My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007-301A
CBCC
>
Official Documents
>
2000's
>
2007
>
2007-301A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/22/2016 12:21:13 PM
Creation date
9/30/2015 11:08:12 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
09/11/2007
Control Number
2007-301A
Agenda Item Number
7.P.
Entity Name
MGE UPS Systems, Inc.
Subject
Renewal Services Agreement IRC Sheriff Office
E911Public Safety Answering Point
Supplemental fields
SmeadsoftID
6551
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M G E <br /> UPS SYSTEMS <br /> Quote ID: CL51339 <br /> Battery Preventive Maintenance Scope of Work <br /> Inspections can be performed on a quarterly, semi-annual or annual basis. The scope of work is defined by the frequency of inspections. MGE <br /> recommends sealed battery inspections semi-annually. <br /> Semi-Annual Inspection or Quarterly Inspections <br /> Check integrity of battery rack or battery cabinet. <br /> Check the general appearance and cleanliness of battery system. <br /> Visually inspect the jars for cracks, leaks, or excessive bulging. <br /> Check for evidence of corrosion at the terminal post and connectors. <br /> Check hardware torque on 10 % of the battery connectors to manufacture specifications. <br /> Measure and record ambient air temperature of battery room. <br /> Using Albercorp cellcorder, or equivalent, test equipment record DC voltage and internal <br /> resistance on entire battery string(s). <br /> Measure and record the system DC float voltage and DC charge current. <br /> Measure and record the AC ripple voltage or AC ripple current. <br /> Provide a report detailing any deficiencies and recommend a corrective action . <br /> Documentation shall provide necessary data for the manufacturer's warranty requirements. <br /> Annual Inspections <br /> Includes all 11 items above. <br /> Re-torque all battery connections to manufacture specifications. <br /> Note 1 : Battery PMs require the unit to be placed in Maintenance Bypass for the duration of the PM. While in Maintenance Bypass your critical load <br /> will be unprotected from any utility power problems. <br /> Note 2: Battery terminal cleaning to correct corrosion and oxidation will be implemented when required. <br /> Note 3: Battery inspections do not include battery replacement. <br /> Note 4: The Albercop cellcorder places a 70 to 75 amp load across each battery and will record both battery float voltage and internal resistance. <br /> These values are used as a predicative tool for early detection of a possible failure when compared to manufacture specifications. <br /> MGE UPS SYSTEMS, INC. 1660 Scenic Avenue, Costa Mesa, California 92626 <br />
The URL can be used to link to this page
Your browser does not support the video tag.