My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-417A
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-417A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2016 9:58:52 AM
Creation date
10/1/2015 1:11:44 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
12/16/2008
Control Number
2008-417A
Agenda Item Number
8.H.
Entity Name
Sheltra & Son Construction
Subject
Enclave Subdivision Contract, Specifications
Area
The Enclave Subdivision
Project Number
0816
Bid Number
2009019
Supplemental fields
SmeadsoftID
8214
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D . CONTROL WIRES : Shall be installed in a neat and orderly fashion <br /> underneath the main and lateral pipes , if possible . Ten - inch loops shall be <br /> provided at each valve where control wires are connected . All wires <br /> passing under existing or future paving , construction , etc . , shall be <br /> encased in plastic pipe as specified , extending at least twelve inches <br /> beyond edges of paving or construction . <br /> E . TESTING : All main lines shall be hydrostatically tested in the presence of <br /> the Owner' s representative at a pressure of 40 psi for a period of time not <br /> less than four (4 ) hours , should any leaks be found , they shall be repaired . <br /> The line shall then be retested until satisfactory . All lateral lines <br /> downstream from the remote control valves shall be visually inspected for <br /> leaks , should any be found , they shall be repaired . The line shall then be <br /> retested until satisfactory . <br /> F . BACKFILL AND COMPACTING : After system is approved or sections <br /> thereof, backfill excavations and trenches with clean soil , free of rubbish . <br /> Backfill for all trenches , regardless of the type of pipe covered shall be <br /> compacted to a minimum 90 % of its maximum density (AASHTO T- 180 ) . <br /> Dress off all areas to finish grades . <br /> G . PUMP ENCLOSURE : <br /> 1 . Pump house shall be allied fiberglass model FPH 4 x 4 or approved <br /> equal onto 4 " thick concrete slab . <br /> 2 . Provide adequate interior space for maintenance . Approx . size : 4 ' x <br /> 4 ' x 3 ' tall . Increase size if required by size of pump and pressure <br /> tank . <br /> 3 . Submit shop drawings for review prior to constructing . <br /> H . FINAL ADJUSTMENT : Balance and adjust the irrigation system <br /> components for efficient , proper operation . This includes controller <br /> synchronization as well as individual settings of control stations . <br /> 3 . INSTRUCTIONS : <br /> A . LABELS <br /> 1 . Number each zone valve box on underside of valve box cover with <br /> a black waterproof marker for reference . Numbers shall match the <br /> zone numbers on the drawings . <br /> 2 . Number each zone valve control wire at the controller with a <br /> waterproof marker and tags . Numbers shall match the zone <br /> numbers on the drawings . <br /> B . MAINTENANCE <br /> 1 . Maintain the irrigation system until final acceptance of the work . <br /> Maintenance shall include work , materials and replacements <br /> necessary to insure a complete properly operating system . <br /> F :\Engineering\Special Proj ects\Enc lave Subdivision\Contract Documents\Contract Documents\The Enclave. doc\00205 - Landscape & Irrigation <br /> Specifications for Contract2 .doc 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.