My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-260A
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-260A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2016 12:05:06 PM
Creation date
10/1/2015 12:30:10 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Addendum
Approved Date
08/19/2008
Control Number
2008-260A
Agenda Item Number
8.R.
Entity Name
SPS Contracting
Subject
Petition Paving Contract
Area
1st.Rd.-35th to 32nd.Avenue;10th Ct.SW-Oslo Rd.to 7thSt.SW
Project Number
0522,0436
Bid Number
2008062
Supplemental fields
SmeadsoftID
7534
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site which was not shown or indicated , or not property monuments by professionally qualified <br /> shown or indicated with reasonable accuracy in personnel . <br /> the Contract Documents , CONTRACTOR shall , <br /> promptly after becoming aware thereof and 4 . 06 Hazardous Environmental Condition at Site <br /> before further disturbing conditions affected <br /> thereby or performing any Work in connection A. Reports and Drawings: Reference is made to <br /> therewith (except in an emergency as required the Supplementary Conditions for the identification of <br /> by paragraph 6 . 16 .A), identify the owner of those reports and drawings relating to a Hazardous <br /> such Underground Facility and give written Environmental Condition identified at the Site, if any, <br /> notice to that owner and to OWNER and ENGI- that have been utilized by the ENGINEER in the <br /> NEER. ENGINEER will promptly review the preparation of the Contract Documents . <br /> Underground Facility and determine the extent, <br /> if any, to which a change is required in the B . Limited Reliance by CONTRACTOR on <br /> Contract Documents to reflect and document Technical Data Authorized: CONTRACTOR may rely <br /> the consequences of the existence or location upon the general accuracy of the "technical data" <br /> of the Underground Facility. During such time, contained in such reports and drawings , but such <br /> CONTRACTOR shall be responsible for the reports and drawings are not Contract Documents . <br /> safety and protection of such Underground Such "technical data" is identified in the <br /> Facility. Supplementary Conditions . Except for such reliance <br /> on such "technical data," CONTRACTOR may not rely <br /> 2 . If ENGINEER concludes that a upon or make any Claim against OWNER, <br /> change in the Contract Documents is required , ENGINEER or any of ENGINEER's Consultants with <br /> a Work Change Directive or a Change Order respect to : <br /> will be issued to reflect and document such <br /> consequences . An equitable adjustment shall 1 . the completeness of such reports <br /> be made in the Contract Price or Contract and drawings for CONTRACTOR's purposes , <br /> Times , or both , to the extent that they are including , but not limited to , any aspects of <br /> the <br /> attributable to the existence or location of any means, methods , techniques , sequences and <br /> Underground Facility that was not shown or procedures of construction to be employed by <br /> indicated or not shown or indicated with CONTRACTOR and safety precautions and <br /> reasonable accuracy in the Contract programs incident thereto ; or <br /> Documents and that CONTRACTOR did not <br /> know of and could not reasonably have been 2 , other data , interpretations , opinions <br /> expected to be aware of or to have anticipated , and information contained in such reports or <br /> If OWNER and CONTRACTOR are unable to shown or indicated in such drawings; or <br /> agree on entitlement to or on the amount or <br /> extent, if any, of any such adjustment in 3 . any CONTRACTOR interpretation of <br /> Contract Price or Contract Times , OWNER or or conclusion drawn from any "technical data" <br /> CONTRACTOR may make a Claim therefor as or any such other data, interpretations , opinions <br /> provided in paragraph 10 .05 . or information . <br /> 4 .05 Reference Points C . CONTRACTOR shall not be responsible for <br /> any Hazardous Environmental Condition uncovered or <br /> A. OWNER shall provide engineering surveys to revealed at the Site which was not shown or indicated <br /> establish reference points for construction which in in Drawings or Specifications or identified in the <br /> ENGINEER's judgment are necessary to enable Contract Documents to be within the scope of the <br /> CONTRACTOR to proceed with the Work. CON- Work. CONTRACTOR shall be responsible for a <br /> TRACTOR shall be responsible for laying out the Hazardous Environmental Condition created with any <br /> Work, shall protect and preserve the established materials brought to the Site by CONTRACTOR, <br /> reference points and property monuments , and shall Subcontractors , Suppliers , or anyone else for whom <br /> make no changes or relocations without the prior CONTRACTOR is responsible , <br /> written approval of OWNER. CONTRACTOR shall <br /> report to ENGINEER whenever any reference point or D . If CONTRACTOR encounters a Hazardous <br /> property monument is lost or destroyed or requires Environmental Condition or if CONTRACTOR or <br /> relocation because of necessary changes in grades or anyone for whom CONTRACTOR is responsible <br /> locations , and shall be responsible for the accurate creates a Hazardous Environmental Condition , <br /> replacement or relocation of such reference points or CONTRACTOR shall immediately: (i) secure or <br /> otherwise isolate such condition ; (ii) stop all Work in <br /> 00700 - General Conditions <br /> 00700 - 13 <br /> F:\Engineering\Petition Paving\0522 1st Rd. from 32nd Ave. to 35th Ave\Bid Documents\00700 - General Conditions.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.