My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-307B
CBCC
>
Official Documents
>
2000's
>
2008
>
2008-307B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2016 11:48:07 AM
Creation date
10/1/2015 12:40:00 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/23/2008
Control Number
2008-307B
Agenda Item Number
8.O.
Entity Name
Timothy Rose Contracting
Subject
Contract and Specifications Eagle Trace Subdivision Phase II
Area
NE Corner of Kings Hwy. and 61st. St. Eagle Trace Subdivision
Project Number
0813
Bid Number
2008074
Supplemental fields
SmeadsoftID
7603
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E . VALVES USED WITH RECLAIMED WATER SHALL BE COLORED <br /> PURPLE OR IDENTIFIED BY OTHER ACCEPTED MEANS AS <br /> DESCRIBED IN S62-610FAC TO DIFFERENTIATE RECLAIMED <br /> WATER FROM DOMESTIC OR OTHER WATER . <br /> VALVE BOXES <br /> A. USE VALVE BOXES THAT ARE CONSTRUCTED TO WITHSTAND <br /> TRAFFIC LOADS COMMON TO THE AREA IN WHICH THEY ARE <br /> INSTALLED . THEY SHOULD BE SIZED TO ALLOW MANUAL <br /> OPERATION OF THE ENCLOSED VALVES <br /> WITHOUT EXCAVATION , <br /> B . EACH VALVE BOX SHOULD BE PERMANENTLY LABELED TO <br /> IDENTIFY ITS CONTENTS , <br /> C . VALVE BOXES USED WITH RECLAIMED WATER SHALL BE <br /> PURPLE OR IDENTIFIED BY OTHER ACCEPTED MEANS AS <br /> DESCRIBED IN S62-610 FAC TO DIFFERENTIATE RECLAIMED <br /> WATER FROM DOMESTIC OR OTHER WATERS , <br /> LOW VOLTAGE WIRING <br /> A . ALL LOW VOLTAGE WIRE , WHICH IS DIRECTLY BURIED , MUST BE <br /> LABELED FOR DIRECT BURIAL . WIRE NOT LABELED FOR DIRECT <br /> BURIAL MUST BE INSTALLED IN WATERTIGHT CONDUITS , AND <br /> BE UL LISTED TWN OR THHN TYPE WIRE AS DESCRIBED IN THE <br /> NEC . <br /> B . CONNECTIONS ARE TO BE MADE USING UL APPROVED DEVICES <br /> SPECIFICALLY DESIGNED FOR DIRECT BURIAL , <br /> IRRIGATION CONTROLLERS <br /> A. ALL IRRIGATION CONTROLLERS SHALL BE UL LISTED , CONFORM <br /> TO THE PROVISIONS OF THE NATIONAL ELECTRIC CODE , AND <br /> PROPERLY GROUNDED IN ACCORDANCE WITH <br /> MANUFACTURER'S RECOMMENDATIONS , THE CONTROLLER <br /> HOUSING OR ENCLOSURE SHALL PROTECT THE CONTROLLER <br /> FROM THE HAZARDS OF THE ENVIRONMENT IN WHICH IT IS <br /> INSTALLED , <br /> B . USE CONTROLLERS THAT ARE PROGRAMMABLE FOR VARYING <br /> IRRIGATION DURATIONS THAT ARE CONSISTENT WITH THE <br /> WATER TO BE APPLIED IN EACH ZONE . <br /> C . EQUIP COMMERCIAL INSTALLATIONS USING SOLID-STATE <br /> CONTROLS WITH SURGE SUPPRESSORS ON THE PRIMARY AND <br /> SECONDARY WIRING , <br /> PUMPS AND WELLS <br /> A . IRRIGATION PUMP ELECTRICAL CONTROL SYSTEMS MUST <br /> CONFORM TO NEC AND LOCAL BUILDING CODES . <br /> F:\Engineering\Special Projects\Eagle Trace Phase 2\Contract Documents\Eagle Trace Subdivision Phase <br /> II\IRRIGATION SPECIFICATIONS from W. F. McCain .doc . 3 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.