Laserfiche WebLink
MOUNDING SHALL NOT BE USED TO BRING THE PIPE TO FINAL <br /> GRADE . <br /> I . ENDS OF PIPE SHALL BE CLOSED TO PREVENT ENTRY OF <br /> FOREIGN MATERIALS WHEN PIPE LAYING IS NOT IN PROGRESS . <br /> J . PIPE SLEEVES MUST BE USED TO PROTECT PIPES OR WIRES <br /> INSTALLED UNDER PAVEMENT OR ROADWAYS , USE PIPE <br /> SLEEVES AT LEAST TWO PIPE SIZES LARGER THAN THE <br /> CARRIER PIPE OR TWICE THE DIAMETER OF THE WIRE BUNDLE <br /> TO BE PLACED UNDER THE PAVING OR ROADWAY , AND <br /> EXTENDING A MINIMUM OF 3 FEET BEYOND THE PAVED AREA <br /> OR AS REQUIRED BY THE FLORIDA DEPARTMENT OF <br /> TRANSPORTATION ( FDOT) . USE SLEEVE PIPE WITH WALL <br /> THICKNESS AT LEAST EQUAL TO THE THICKNESS OF SCHEDULE <br /> 40 OR PR 160 PIPE , WHICHEVER IS THICKER . <br /> PIPING UNDER PAVED TRAFFIC AREAS SHALL BE ENCASED IN <br /> FULL LENGTHS OF SLEEVING MATERIAL TO AVOID PLACEMENT <br /> OF JOINTS UNDER PAVEMENT IF POSSIBLE . USE THE SAME <br /> TECHNIQUES TO PLACE PIPE SLEEVES TO SERVE AS CONDUITS <br /> FOR AUTOMATIC CONTROL WIRES OR TUBING , SLEEVE <br /> MATERIAL MAY BE STEEL OR PLASTIC PIPE , SUITABLE TO SLIDE <br /> PIPE , WIRE OR TUBING THROUGH , PROPER BACKFILL AND <br /> COMPACTION PROCEDURES SHOULD BE FOLLOWED . <br /> K . PIPES CONVEYING RECLAIMED WATER SHALL BE SEPARATED <br /> FROM OTHER PIPING OR UTILITY SERVICES BY 3 FEET <br /> HORIZONTAL DISTANCE . AN 18— INCH VERTICAL SEPARATION <br /> SHALL BE MAINTAINED WHERE RECLAIMED LINES CROSS <br /> OTHER PIPING OR UTILITY SERVICES . <br /> CONTROL VALVE INSTALLATION <br /> A . VALVE INSTALLATION SHALL ALLOW ENOUGH CLEARANCE FOR <br /> PROPER OPERATION AND MAINTENANCE . WHERE VALVES ARE <br /> INSTALLED UNDERGROUND , THEY SHALL BE PROVIDED WITH A <br /> VALVE BOX WITH COVER EXTENDING FROM GRADE TO THE <br /> BODY OF THE VALVE , THE TOP OF THE VALVE BODY SHOULD <br /> HAVE A MINIMUM OF 6 INCHES OF COVER IN NON —TRAFFIC AND <br /> NON —CULTIVATED AREAS AND 18 INCHES OF COVER IN TRAFFIC <br /> AREAS , <br /> Be AUTOMATIC CONTROL VALVES INSTALLED UNDERGROUND <br /> SHALL BE INSTALLED IN A VALVE BOX , IF AN AUTOMATIC VALVE <br /> IS INSTALLED UNDER EACH SPRINKLER , THEN THE VALVE BOX <br /> MAY BE OMITTED . VALVES MUST BE INSTALLED WITH ENOUGH <br /> CLEARANCE FOR OPERATION AND MAINTENANCE . <br /> C . INSTALL VALVE BOXES SO THAT THEY DO NOT REST ON THE <br /> PIPE , THE BOX COVER DOES NOT CONFLICT WITH THE VALVE <br /> STEM OR INTERFERE WITH VALVE OPERATION AND SO THAT <br /> THE VALVE BOX LIDS ARE FLUSH WITH THE GROUND SURFACE . <br /> F:\Engineering\Special Projects\Eagle Trace Phase 2\Contract Documents\Eagle Trace Subdivision Phase <br /> II\IRRIGATION SPECIFICATIONS from W. F . McCain . doc . 8 . <br />