My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-377
CBCC
>
Official Documents
>
2000's
>
2006
>
2006-377
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2016 11:56:09 AM
Creation date
9/30/2015 10:15:19 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Plan
Approved Date
10/24/2006
Control Number
2006-377
Agenda Item Number
11.J.5.
Entity Name
Indian River County Department of Utility Services
Subject
Water & Wastewater Standards-updated October 2006
Supercedes all previous versions
Supplemental fields
SmeadsoftID
5936
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
234
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F . The Contractor shall make all arrangements necessary with an <br /> - <br /> independent commercial laboratory approved by the Department of <br /> Environmental Health for the collection and examination of samples of <br /> water from disinfected water mains . Note: The Contractor may not collect <br /> his own samples. These samples shall be examined for compliance with <br /> the Department of Environmental Health 's and Florida Department of <br /> Environmental Protection's requirements . Sampling shall be made daily <br /> and continuously until two successive examinations are found <br /> satisfactory. Should one examination be found unsatisfactory, the line <br /> shall be flushed and disinfected again . PVC Certified copies of all <br /> laboratory analyses shall be provided to the IRCDUS. The cost al all <br /> sampling , flushing and disinfecting shall be included in the contract price . <br /> IRCDUS personnel shall operate all valves and be present to determine <br /> and control the volume of water used for flushing . <br /> TABLE 10 — 1 <br /> — <br /> Chlorine Required to Produce a 25-mg/L Concentration in 100ft of Pipe by <br /> Diameter _ <br /> 1 -percent <br /> Pipe 100-percent Chlorine <br /> Diameter Chlorine Solution <br /> ( inches) (pounds) (gallons) <br /> 4 0. 013 0 . 16 <br /> 6 0. 030 0 . 36 — <br /> 8 0. 054 0.65 <br /> 10 0. 085 1 . 02 <br /> 12 0. 120 1 .44 — <br /> 16 0. 217 2 . 60 <br /> For Pipes larger than 16-inches in diameter see <br /> AWWA Standard Specifications C-651 -99 <br /> 10 .04 TESTING OF GRAVITY SEWERS <br /> — <br /> A. Leakage test by exfiltration and infiltration , as described below, shall be <br /> made on all pipes . <br /> B . Exfiltration tests shall be made on all pipes after backfilling . All sewers <br /> shall be tested such that water is filled to the rim of the lowest manhole <br /> being tested within each section being tested , as directed by the <br /> IRCDUS. Mechanical plugs shall be used on the gravity sewer system in <br /> such a manner that the air can be released from the sewer while it is <br /> being filled with water. The test shall be continued for one hour and .. <br /> provisions shall be made for measuring the amount of water required to <br /> maintain the water at a constant level during this period . If test results are <br /> unsatisfactory, the Engineer and/or IRCDUS may direct that additional <br /> test be made on any section or the entire pipe . <br /> — <br /> 10 - 4 <br /> — <br />
The URL can be used to link to this page
Your browser does not support the video tag.