My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-377
CBCC
>
Official Documents
>
2000's
>
2006
>
2006-377
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2016 11:56:09 AM
Creation date
9/30/2015 10:15:19 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Plan
Approved Date
10/24/2006
Control Number
2006-377
Agenda Item Number
11.J.5.
Entity Name
Indian River County Department of Utility Services
Subject
Water & Wastewater Standards-updated October 2006
Supercedes all previous versions
Supplemental fields
SmeadsoftID
5936
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
234
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> elevation shall be a minimum of 12-inches above the associated elevations ,. <br /> shown on the FIRM ( Flood Insurance Rate Map) or 12 inches above the 25-year <br /> — 24-hour storm event elevation , whichever is greater. <br /> r <br /> I . In IRCDUS maintained lift station , pumps shall be per the Approved <br /> Manufacturer's Product List. If a grinder pump is proposed , see Approved <br /> Manufacturer's Product List. Only grinder pumps under 10 . 0 hp are permitted _ <br /> unless approved by IRCDUS . <br /> J . Lift Station Calculation Checklist (all assumptions shall be listed in calculations <br /> and in an orderly fashion) : r <br /> 1 . Design flow <br /> 2. Downstream force main size & down stream head pressure (in psi or feet r <br /> of water) <br /> 3. TDH of pumps shall exceed system head curve <br /> 4 . Pump selection make, model , HP , impeller r <br /> 5 . a. Wet well dimensions <br /> b . Operating cycle and draw down time <br /> 6 . Buoyant computations Documentation: r <br /> a . Buoyant force <br /> b. Downward force <br /> c. Safety factor _ <br /> d . Depth to water table <br /> 7. Designer name, date , design firm, Indian River County project number, <br /> project name, designer name of revisions <br /> r <br /> K. Only one influent gravity main is allowed into the lift station . The first upstream <br /> manhole from the lift station must be located within 20 feet +/- 1 -foot of the lift <br /> station and as approved by IRCDUS . <br /> L. The owner of a private lift station must have a maintenance agreement with a <br /> qualified firm (individual) to maintain the lift station . A label must be posted on r <br /> the lift station stating the name and 24-hour phone number of the responsible <br /> firm before lift station may be placed into operation . A copy of a maintenance <br /> contract is to be submitted prior to issuance of the Utility Construction Permit. r <br /> Maintenance contract must be renewed annually with copies of said contract <br /> submitted to IRCDUS. Owners of private lift stations shall submit a letter to <br /> IRCDUS acknowledging that the lift station is substandard to the County <br /> r <br /> Standard lift station . <br /> 11 . 03 WATER DISTRIBUTION <br /> r <br /> A. All water mains shall be constructed in accordance with the Indian River County <br /> Water Master Plan , latest edition , or current AWWA Standard Specifications and <br /> current regulatory agencies requirements. r <br /> B . All distribution systems shall be properly looped , where feasible , and valved to <br /> provide maximum flexibility in providing service . r <br /> r <br /> 11 - 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.