My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-377
CBCC
>
Official Documents
>
2000's
>
2006
>
2006-377
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2016 11:56:09 AM
Creation date
9/30/2015 10:15:19 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Plan
Approved Date
10/24/2006
Control Number
2006-377
Agenda Item Number
11.J.5.
Entity Name
Indian River County Department of Utility Services
Subject
Water & Wastewater Standards-updated October 2006
Supercedes all previous versions
Supplemental fields
SmeadsoftID
5936
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
234
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> A. Excavation for all utilities and/or house connections shall be adequately guarded <br /> with barricades and lights, so as to protect the public from hazard . Streets , <br /> sidewalks , driveways, curbs , parkways and other public property disturbed in the <br /> course of the work shall be restored in a manner satisfactory to the IRCDUS • <br /> and/or Public Works . <br /> B . Foundation material used for pipe bedding , from a minimum 6-inch distance <br /> below the pipe invert to the bottom 12-inches above the top of the pipe , shall be <br /> bank run sand and gravel . <br /> C. All gravity sewer installation procedures must be in accordance with pipe <br /> manufacturer's recommendations. All gravity sewers and force mains shall be <br /> installed to have a minimum depth of 36-inches. Installation of gravity sewers <br /> shall be controlled by use of a laser to maintain proper grade. A maximum • <br /> tolerance of %' dip will be accepted in gravity sewer construction. A 2-inch wide <br /> magnetic I . D . tape shall be placed continuously in the trench over all pipes, 12- <br /> inches below grade . • <br /> 1 . Trench — Trench width shall be kept to a minimum necessary for <br /> installation of the pipe and shall comply with current OSHA requirements. • <br /> The trench bottom shall be graded uniformly to match the slope of the pipe . <br /> 2 . Backfill — Only good quality backfill , free of stones , hardpan materials , <br /> roots, rocks , broken cement or other debris that might be damaging to the <br /> pipe shall be used . Backfill shall be placed in the trench in uniform lifts of <br /> 12-inches . <br /> • <br /> 3 . Compaction — All fill must be compacted by hand tamping from under the <br /> pipe us to the center line . Backfill shall be compacted in lifts up to the <br /> surface to achieve a minimum compaction of 98% of maximum density in • <br /> roadways , shoulders, and easements , in accordance with AASHTO <br /> Specifications T-180 and ASTM D-2167 . <br /> • <br /> 4 . Dewatering — Construction shall be accomplished in a dry trench . Well <br /> pointing may be required as necessary. All water entering excavations or <br /> other parts of the work shall be contained , collected and pumped to • <br /> suitable places for disposal , as permitted by local and state regulation . <br /> 5. Sheeting — Sheeting and shoring shall be installed as may be necessary <br /> for the protection of the work, preservation of adjacent property and • <br /> structures and the safety of employees. Sheeting and backing shall be <br /> uniform to OSHA requirements . <br /> • <br /> D . Installation of force mains (sewer or reused water) shall be in accordance with <br /> latest AWWA Standard Specifications C- 600 and the installation specifications <br /> for water lines in the Water Distribution Section , irrespective of the type of pipe • <br /> selected . A 2-inch wide magnetic I . D . tape and tracer wire shall be placed <br /> continuously in the trench overall pipes per Detail M-14 , 12-inches below grade . <br /> • <br /> 1 . Trench — Trench width shall be kept to a minimum necessary for pipe <br /> installation and shall comply with current OSHA requirements . The trench <br /> 11 - 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.