Laserfiche WebLink
carbide ring with each pair held in contact by a separate <br /> spring , so that the outside pressure assists spring <br /> compression in preventing the seal faces from opening . <br /> The compression spring shall be protected against <br /> exposure to the pumped liquid . The pumped liquid shall <br /> be sealed from the oil reservoir by one face seal and <br /> sealed from the oil reservoir from the motor chamber by <br /> the other. The seals shall require neither maintenance nor <br /> adjustment, and shall be easily replaced . Conventional <br /> double mechanical seals with a single spring between the <br /> rotating faces , requiring constant differential pressure to <br /> effect sealing and subject to opening and penetration by <br /> pumping forces , shall not be considered equal to tandem <br /> seal specified and required . <br /> 4 . A sliding guide bracket shall be an integral part of the <br /> pumping unit, and the pump casing shall have a machined <br /> connecting flange to connect with the cast iron discharge <br /> connection , which shall be bolted to the floor of the sump <br /> with stainless steel anchor bolts and so designed as to <br /> receive the pump connection without the need of any bolts <br /> or nuts . Sealing of the pumping units to the discharge <br /> connection shall be accomplished by a simple linear <br /> downward motion of the pump , with the entire weight of the <br /> pumping unit guided by 304 stainless steel guides which <br /> will press it tightly against the discharge connection . No <br /> portion of the pump shall bear directly on the floor of the <br /> sump , and no rotary motion of the pump shall be required <br /> for sealing . <br /> 5 . Pump motors shall be housed in an air-filled , watertight <br /> casing . Motors shall be a NEMA Design B with a 1 . 15 <br /> service factor. Insulation shall be moisture-resistant NEMA <br /> Class F with a maximum temperature rise of 90 degrees <br /> Celsius above ambient temperature (4 degrees Celsius ) . <br /> Motor characteristics are noted on the Drawings . Pump <br /> motors shall have cooling characteristics suitable to permit <br /> continuous operation , in a totally , partially or non- <br /> submerged condition . Each motor shall incorporate an <br /> ambient temperature compensated overheat sensing <br /> device and a moisture sending device wired in series . The <br /> protective devices shall be wired into the pump controls in <br /> such a way that if either device operates , the pump will <br /> shut down . The devices shall be self- resetting . The cable <br /> shall be fixed to the pump using a watertight trumpet <br /> assembly. The pump shall be capable of running <br /> continuously in a totally dry condition under full load , <br /> without damage , for extended periods . Before final <br /> acceptance , a field running test demonstrating this ability, <br /> with four (4 ) hours of continuous operation (water supplied <br /> by the contractor) under the above conditions , shall be <br /> 8 - 5 <br />