H . Gravity sewers must be installed in front ( under driveway/roadway pavement) of <br /> new buildings and/or under roadway pavement in dedicated Rights-of-Way, all <br /> accessible to maintenance equipment. <br /> I . Gravity Mains shall be installed a minimum of 10 feet from any existing or <br /> proposed structure (walls , trees , transformer pads , etc. ) . <br /> 11 . 02 WASTEWATER PUMPING STATIONS <br /> A. A Remote Telemetry Unit ( RTU ) shall be included in all pump stations that are to <br /> be dedicated to Indian River County, <br /> B . Wastewater pumping stations shall be designed to peak ultimate development <br /> flow from all contributory areas , in accordance with the Indian River County <br /> Wastewater Master Plan . Design average daily flow and peak hour flow shall be <br /> as set forth in Section 11 . 01 . <br /> C . Design of private lift stations that may be dedicated to the County at a later date <br /> shall meet IRCDUS design standards and . shall be approved by IRCDUS . Any <br /> private station that does not meet IRCDUS design standards will not be taken <br /> over by the IRCDUS . Owners of private stations shall sign a form acknowledging <br /> future upgrade requirements if Owner is to dedicate a private station to the <br /> IRCDUS at a later date . <br /> D . At least 2 pumps shall be provided for stations handling flows of 700 gallons per <br /> minute (gpm ) or less . A minimum of 3 pumps shall be provided in stations where <br /> peak design flow exceeds 700 gpm unless otherwise approved by IRCDUS . In <br /> all cases , standby-pumping capability shall be provided such that if any one <br /> Pump is out of service , an alternate unit is available at equal or greater capacity. <br /> E . The sewage pump system shall be capable of pumping the design peak flow at <br /> the maximum computed system total dynamic head . Maximum residual head <br /> within existing force mains shall be obtained and coordinated through IRCDUS. <br /> F . Pumps shall be capable of passing spheres of at least 3-inches in diameter, and <br /> Pump suction and discharge piping shall be at least 4-inches in diameter. <br /> Grinder pumps shall be used when riser pipes in wet well are less than 3-inches . <br /> Minimum valve (all types ) size is 4-inches . <br /> G . Wet wells shall be a minimum of 6 -feet in diameter ( ID ) . All wet wells shall be <br /> sized to provide a minimum pump cycle of 15 minutes . Pumps shall be designed <br /> to provide a minimum pump run time equal to half the cycle time . Additionally, <br /> wet wells shall provide sufficient space for installed equipment and required <br /> suction pipe submergence and spacing . The wet well floor shall have a minimum <br /> slope of one-to-one to the hopper bottom . <br /> H . A separate valve vault shall be provided to house the gate valves , check valves <br /> and the emergency pump connection . The vault shall be of sufficient size to <br /> allow for installation , removal and maintenance of the valves . The bottom of the <br /> valve vault shall be a minimum of 12-inches above the high water level of the <br /> associated development. The wet well top elevation and the valve vault top <br /> 11 - 2 <br />