Laserfiche WebLink
Sewerage Facilities <br /> Concrete (Wet Wells, Tanks , Submerged or Severe Conditions — Color – Series 46-413 Coal Tar <br /> Channels , etc. ) Ri ortex 3324 Enamel 104-----Series 104 <br /> Metal (Equipment, Piping Systems , Submerged , or Intermittently Submerged , or Primer Series 661211 — <br /> Tanks , etc. ) Extreme Conditions Finish 46-413 (2 coats , 8 <br /> mil . ea . )--46H ( 1 coat, 16 <br /> mil . <br /> Metal (moving Parts – Chains , Gates , Submerged or Intermittently Submerged Grease Coating <br /> etc. <br /> Water Facilities <br /> Concrete (Tanks , Troughs , Basins , Submerged , or Intermittently Submerged Primer Series 20- 1255, <br /> etc. ) Beige 3-5 mil – Filler <br /> Series 63 – 1500, as <br /> applicable –Finish Series <br /> 20-BB82 , 4-6 mils <br /> Metal (Tanks , Piping Systems , Submerged , or Intermittently Submerged Primer Series 20- 1255, <br /> Equipment) Beige 3-5 mil – Filler <br /> Series 63 – 1500, as <br /> applicable –Finish Series <br /> 20-BB82, 4-6 mils <br /> Special Notes : <br /> 1 . All galvanized or other nonferrous surfaces requiring painting shall be pretreated with an approved <br /> conditioner or passivator, as recommended by the paint manufacturer, prior to application of the painting <br /> system . <br /> 2. Bituminous coated pipe shall be coated with Inertol Tar Stop or approved equal , as recommended prior <br /> to application of the painting system. <br /> 3. Metal surfaces , in contact with concrete or masonry, shall be protected with Tnemec46-413 Coal Tar <br /> coating or approved equal , as recommended . This provision shall not apply to concrete reinforcement, <br /> piping and fittings , or conduits and accessories . <br /> 13 . 05 ELECTRIC <br /> A. General <br /> The provisions of this Section , including other specific design <br /> considerations , shall be the minimum standards as applicable to all <br /> sewage and water facilities . <br /> It shall be the responsibility of the Contractor to advise the <br /> appropriate electrical power company regarding the proposed facility <br /> prior to installation and to make the necessary provisions for service <br /> thereto . <br /> In accordance with the provisions of the General Conditions , <br /> complete shop drawings and technical data shall be submitted to the <br /> IRCDUS including , but not limited to , motor control centers and <br /> control systems , with wiring diagrams and components ; <br /> manufacturer' s data for switches , transformers , relays , lighting <br /> fixtures and other accessories ; panel boards ; and all other applicable <br /> information . <br /> Be Materials , Equipment and Installation <br /> 13- 14 <br />