Laserfiche WebLink
e <br /> SECTION 02532 <br /> APPURTENANCES FOR GRAVITY SEWER SERVICES <br /> PART 1 - SCOPE <br /> This section describes the materials for appurtenances to be used in construction of gravity <br /> sewerage services as shown on the Plans and specified. <br /> PART 2 - SEWER CONNECTIONS AT MANHOLES AND WET WELLS <br /> The first joint shall be not more than 24" from the outside of the manhole . PVC pipe must <br /> enter the manhole through an elastomeric manhole coupling as manufactured by Kor-N-Seal, <br /> Inc. or approved equal. <br /> PART 3 - CLEAN OUTS <br /> Clean-outs shall be provided immediately prior to the service lateral end and where shown or <br /> specified. Clean-out sizes for pipe 8 inches or larger in diameter shall be not less than 6 <br /> inches in diameter. Clean out sizes for pipe less than 8 inches in diameter shall be of the <br /> same diameter as the pipe except at the ends of service laterals where they may be 4 inch <br /> in diameter as shown on the Drawings . <br /> Materials for Clean-out construction shall be as shown on the drawings. <br /> END OF SECTION <br /> SDIRC Middle School "BB" 02532 - Appurtenances for Gravity Sewer <br /> 02532- 1 <br /> z <br /> e <br />