Laserfiche WebLink
B . Warm-Air Dryer: Total (6) <br /> 1 . Mounting: Surface mounted. <br /> 2 . Operation: Touch-button activated with timed power cut-off switch. <br /> a. Operation Time : 30 to 40 seconds . <br /> 3 . Cover Material and Finish: Stainless steel, No . 4 finish (sarin) . <br /> 4 . Electrical Requirements : 115 V, 20 A, 2300 W . <br /> ,. 2 .4 CHILDCARE ACCESSORIES <br /> A. Available Manufacturers : Subject to compliance with requirements, manufacturers offering products that <br /> may be incorporated into the Work include, but are not limited to, the following: <br /> 1 . American Infant Care Products Inc . <br /> 2 . Koala Corporation. <br /> 3 . Safe-Strap Company, Inc . <br /> B . Diaper-Changing Station Total (2) : <br /> 1 . Description: Horizontal unit that opens by folding down from stored position and with child- <br /> protection strap . <br /> a. Engineered to support a minimum of 250-1b ( 113 -kg) static load when opened. <br /> 2 . Mounting: Surface mounted, with unit projecting not more than 4 inches ( 100 rum) from wall <br /> when closed. <br /> 3 . Operation: By pneumatic shock-absorbing mechanism. <br /> 4 . Material and Finish: High-density polyethylene in manufacturer' s standard color. <br /> 5 . Liner Dispenser: Built in. <br /> 2 . 5 FABRICATION <br /> A. General: Fabricate units with right seams and joints, and exposed edges rolled. Hang doors and access <br /> panels with full-length, continuous hinges. Equip units for concealed anchorage and with corrosion- <br /> resistant backing plates. <br /> B . Keys : Provide universal keys for internal access to accessories for servicing and resupplying. Provide <br /> minimum of six keys to Owner's representative . <br /> PART 3 - EXECUTION <br /> 3 . 1 INSTALLATION <br /> A. Install accessories according to manufacturers' written instructions, using fasteners appropriate to <br /> substrate indicated and recommended by unit manufacturer. Install units level, plumb, and firmly <br /> anchored in locations and at heights indicated. <br /> B . Grab Bars : Install to withstand a downward load of at least 250 lbf ( 1112 N), when tested according to <br /> method in ASTM F 446 . <br /> ,. Wabasso Beach Park Revised 01/08/08 <br /> Indian River County 10801 - 4 <br /> DAA Project No . 6008 <br />