Entity Name
Ocean Gate General Contractors
Subject
Wabasso Beach Park Restoration
Area
Wabasso Beach
Bid Number
2008032
Supplemental fields
SmeadsoftID
7475
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F . Keep expansion joints free of mortar. <br /> G. Point joints by filling with sealant to comply with requirements in Division 7 Section " Joint Sealants . " <br /> H . Clean glass unit masonry assemblies as work progresses. Remove mortar fns and smears immediately, <br /> using a clean, wet sponge or a scrub brush with stiff fiber bristles. Do not use harsh cleaners, acids, <br /> abrasives, steel wool, or wire brushes when removing mortar or cleaning glass unit masonry assemblies . <br /> I. Install sealant at jambs, heads, mullions and other locations indicated. Prepare joints, including <br /> installation of primer and bond-breaker tape or cylindrical sealant backing, and apply elastomeric sealants <br /> to comply with requirements in Division 7 Section " Joint Sealants. " <br /> J. Construction Tolerances : Set glass block to comply with the following tolerances : <br /> 1 . Variation from Plumb : For lines and surfaces of vertical elements and arris, do not exceed 1 /4 <br /> inch in 10 feet (6 mm in 3 m), 3/8 inch in 20 feet (9 mm in 6 m), or 1 /2 inch in 40 feet ( 12 mm in <br /> 12 m) or more. <br /> 2 . Variation from Level: For bed joints, and other conspicuous lines, do not exceed 1 /4 inch in 20 <br /> feet (6 mm in 6 m) or 1 /2 inch in 40 feet ( 12 mm in 12 m) or more . <br /> 3 . Variation of Linear Building Line : For positions shown in plan and related portions of walls and <br /> partitions, do not exceed 1 /2 inch in 20 feet ( 12 mm in 6 m) or 3/4 inch in 40 feet ( 19 mm in 12 m) <br /> or more. <br /> 4 . Variation in Mortar-Joint Thickness : Do not vary from joint thickness indicated by more than plus <br /> or minus 1 / 16 inch ( 1 . 5 mm) . <br /> 3 .3 CLEANING <br /> A. On surfaces adjacent to glass unit masonry assemblies , remove mortar, sealants, and other residue <br /> resulting from glass-block installation, in a manner approved by manufacturers of materials involved . <br /> B . Remove excess sealants with commercial solvents of type recommended by sealant manufacturer. <br /> Exercise care not to damage sealant in joints. <br /> C . Perform final cleaning of glass unit masonry assemblies when surface is not exposed to direct sunlight. <br /> Start at top of panel using generous amounts of clean water. Remove water with clean, dry, soft cloths ; <br /> change cloths frequently to eliminate dried mortar particles and aggregate . <br /> END OF SECTION 04815 <br /> Wabasso Beach Park <br /> Indian River County <br /> DAA Project No . 6008 <br /> 04815 -5 <br />