My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-021A
CBCC
>
Official Documents
>
2010's
>
2012
>
2012-021A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2015 1:17:58 PM
Creation date
10/1/2015 4:08:43 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
02/14/2012
Control Number
2012-021A
Agenda Item Number
8.D.
Entity Name
Timothy Rose Contractor
Subject
Contract Documents and Specifications
Culvert Replacement
Area
6th Ave. SW North of 23rd. St. SW
Project Number
1136
Bid Number
2012033
Archived Roll/Disk#
112-R-0001
Supplemental fields
SmeadsoftID
10978
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
188
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
scarified or loosened to a depth and then raked smooth and free from debris . Where <br /> the soil is sufficiently loose and clean , the Owner , at his discretion , may authorize the <br /> elimination of ground preparation . <br /> G . Application of Fertilizer : Before applying fertilizer, the soil pH shall be brought to a <br /> range of 6 . 0 - 7 . 0 . <br /> Contractor shall apply two ( 2 ) applications . The initial shall be fertilizer and the second <br /> application shall be " weed and feed " . <br /> The fertilizer shall be spread uniformly over the sodded area at the rate of 436 pounds <br /> per acre , or 10 pounds per 1 , 000 square feet , by a spreading device capable of <br /> uniformly distributing the material at the specified rate . <br /> Contractor shall apply applications as per manufacturer's specification . All tickets from <br /> bags shall be handed over to the County Inspector . <br /> On steep slopes , where the use of a machine for spreading or mixing is not <br /> practicable , the fertilizer shall be spread by hand and raked in and thoroughly mixed <br /> with the soil to a depth of approximately 2 inches . <br /> H . Placing Sod : The sod shall be placed on the prepared surface , with edges in close <br /> contact and shall be firmly and smoothly embedded by light tamping with appropriate <br /> tools . _ <br /> Where sodding is used in drainage ditches , the setting of the pieces shall be staggered <br /> so as to avoid a continuous seam along the line of flow . Along the edges of such <br /> staggered areas , the offsets of individual strips shall not exceed 6 inches . In order to <br /> prevent erosion caused by vertical edges at the outer limits , the outer pieces of sod <br /> shall be tamped so as to produce a featheredge effect . <br /> Where sodding is placed abutting paved shoulder , the contractor is to ensure that the <br /> finished sod elevation is 1 '/2" below paved shoulder . <br /> On slopes greater than 3 : 1 , the Contractor shall prevent the sod from sliding by means <br /> of wooden pegs driven through the sod blocks into firm earth , at suitable intervals . <br /> Sodding shall not be performed when weather and soil conditions are , in the <br /> Engineer' s opinion , unsuitable for proper results . <br /> Sod shall be placed around all structures , equipment pads , etc . <br /> I . Watering : The areas on which the sod is to be placed shall contain sufficient moisture , <br /> as determined by the Engineer, for optimum results . After being placed , the sod shall <br /> be kept in a moist condition to the full depth of the rooting zone for at least 2 weeks . <br /> Thereafter , the Contractor shall apply water as needed until the sod roots and starts to <br /> grow for a minimum of 60 days ( or until final acceptance , whichever is latest ) . <br /> J . Maintenance : The Contractor shall , at his expense , maintain the sodded areas in a <br /> satisfactory condition until final acceptance of the project . Such maintenance shall <br /> include repairing of any damaged areas and replacing areas in which the establishment <br /> of the grass stand does not appear to be developing satisfactorily . <br /> Replanting or repair necessary due to the Contractor' s negligence , carelessness or <br /> 01025- 24 Technical Specifications <br /> F : \Public Works\ENGINEERING DIVISION PROJECTS\ 1136-6th Ave SW--Culvert Replacement N of 23rd St SW\Admim\Contract <br /> Documents\Technical Specifications . doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.