My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-021A
CBCC
>
Official Documents
>
2010's
>
2012
>
2012-021A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2015 1:17:58 PM
Creation date
10/1/2015 4:08:43 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
02/14/2012
Control Number
2012-021A
Agenda Item Number
8.D.
Entity Name
Timothy Rose Contractor
Subject
Contract Documents and Specifications
Culvert Replacement
Area
6th Ave. SW North of 23rd. St. SW
Project Number
1136
Bid Number
2012033
Archived Roll/Disk#
112-R-0001
Supplemental fields
SmeadsoftID
10978
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
188
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8 . 06 Insurance <br /> 9 . 02 Visits to Site <br /> A . OWNER's responsibilities , if any, in respect to <br /> purchasing and maintaining liability and property insur- A . ENGINEER will make visits to the Site at <br /> ance are set forth in Article 5 . intervals appropriate to the various stages of construc- <br /> tion as ENGINEER deems necessary in order to <br /> 8 . 07 Change Orders observe as an experienced and qualified design <br /> professional the progress that has been made and the <br /> A . OWNER is obligated to execute Change quality of the various aspects of CONTRACTOR's <br /> Orders as indicated in paragraph 10 . 03 . executed Work . Based on information obtained <br /> during such visits and observations , ENGINEER , for <br /> 8 . 08 Inspections, Tests, and Approvals the benefit of OWNER , will determine , in general , if <br /> the Work is proceeding in accordance with the Con - <br /> A. OWNER's responsibility in respect to certain tract Documents . ENGINEER will not be required to <br /> inspections , tests , and approvals is set forth in make exhaustive or continuous inspections on the <br /> paragraph 13 . 03 . B . Site to check the quality or quantity of the Work . <br /> ENGINEER's efforts will be directed toward providing <br /> 8 . 09 Limitations on OWNER 's Responsibilities for OWNER a greater degree of confidence that the <br /> completed Work will conform generally to the Contract <br /> A . The OWNER shall not supervise , direct , or Documents . On the basis of such visits and <br /> have control or authority over , nor be responsible for, observations , ENGINEER will keep OWNER informed <br /> CONTRACTOR' s means , methods , techniques , se- of the progress of the Work and will endeavor to guard <br /> quences , or procedures of construction , or the safety OWNER against defective Work . <br /> precautions and programs incident thereto , or for any <br /> failure of CONTRACTOR to comply with Laws and B . ENGINEER's visits and observations are <br /> Regulations xipplicable_ _to —the performance—of_Ahe — . __subject to._aflAhL limitations_-orLENG1NEER s_authoriiy_ <br /> Work . OWNER will not be responsible for and responsibility set forth in paragraph 9 . 10 , and <br /> CONTRACTOR's failure to perform the Work in particularly, but without limitation , during or as a result <br /> accordance with the Contract Documents . of ENGINEER's visits or observations of <br /> CONTRACTOR's Work ENGINEER will not <br /> 8 . 10 Undisclosed Hazardous Environmental supervise , direct , control , or have authority over or be <br /> Condition responsible for CONTRACTOR's means , methods , <br /> techniques , sequences , or procedures of construction , <br /> A . OWNER's responsibility in respect to an or the safety precautions and programs incident <br /> undisclosed Hazardous Environmental Condition is thereto , or for any failure of CONTRACTOR to comply <br /> set forth in paragraph 4 . 06 . with Laws and Regulations applicable to the <br /> performance of the Work . <br /> 8 . 11 Evidence of Financial Arrangements <br /> 9 . 03 Project Representative <br /> A . If and to the extent OWNER has agreed to <br /> furnish CONTRACTOR reasonable evidence that A. If OWNER and ENGINEER agree , ENGI - <br /> financial arrangements have been made to satisfy NEER will furnish a Resident Project Representative <br /> OWNER' s obligations under the Contract Documents , to assist ENGINEER in providing more extensive <br /> OWNER's responsibility in respect thereof will be as observation of the Work . The responsibilities and <br /> set forth in the Supplementary Conditions . authority and limitations thereon of any such Resident <br /> Project Representative and assistants will be as <br /> provided in paragraph 9 . 10 and in the Supplementary <br /> ARTICLE 9 - ENGINEER ' S STATUS DURING Conditions . If OWNER designates another represen - <br /> CONSTRUCTION tative or agent to represent OWNER at the Site who is <br /> not ENGINEER's Consultant, agent or employee , the <br /> responsibilities and authority and limitations thereon of <br /> 9 . 01 OWNER 'S Representative such other individual or entity will be as provided in the <br /> Supplementary Conditions , <br /> A . ENGINEER will be OWNER' s representative <br /> during the construction period . The duties and 9 . 04 Clarifications and Interpretations <br /> responsibilities and the limitations of authority of <br /> ENGINEER as OWNER Is representative during A . ENGINEER will issue with reasonable <br /> construction are set forth in the Contract Documents promptness such written clarifications or interpreta - <br /> and will not be changed without written consent of tions of the requirements of the Contract Documents <br /> OWNER and ENGINEER . as ENGINEER may determine necessary, which shall <br /> 00700 - General Conditions REV 04-07 .doc <br /> 00700 - 27 <br /> F \Public Works\ENGINEERING DIVISION PROJECTS\ 1136-6th Ave SW_ Culvert Replacement N of 23rd St SW\Admim\Contract Documents\00700 - General Conditions <br /> REV 04 -0Tdoc <br />
The URL can be used to link to this page
Your browser does not support the video tag.