Laserfiche WebLink
Table 3 <br /> Tvvical Data Qualifier Codes to be used when Reporting Microbiological Data to the DEP under the Overflow Purchase Order or Contract <br /> others may apply) <br /> Contract Sample received after 6 hours OR analyzed beyond 8 hours. <br /> Requirement <br /> Indicates that the compound was analyzed for but not detected. This symbol shall be used to indicate that the specified <br /> component was not detected. <br /> Rule The value associated with the qualifier shall be the laboratory method detection limit. Unless requested by the client, <br /> less than the method detection <br /> U limit values shall not be reported see "T" above). <br /> Contract Organism was analyzed for but not detected. <br /> Requirement <br /> Indicates that the analyte was detected at or above the method detection limit in both the sample and the associated method <br /> blank and the value of 10 <br /> Rule times the blank value was equal to or greater than the associated sample value . Note : unless specified by the <br /> method, the value in the blank shall not <br /> V be subtracted from associated samples. <br /> Contract Analyte was detected in both samples and method blank. Use this code when the sample result is less than or equal to <br /> 10 times the value of the blank. <br /> Requirement Do not subtract the value of the blankfirom the sample result. <br /> Y Rule The laboratory analysis was from an improperly preserved sample. The data May not be accurate. <br /> Too many colonies were present for accurate counting. Historically, this condition has been reported as "too numerous to <br />count" (TNTC). The "Z" <br /> Rule qualifier code shall be reported when the total number of colonies of all types is more than 200 in all dilutions of <br />the sample. When applicable to the <br /> observed test results, a numeric value for the colony count for the microorganism tested shall be estimated from the highest <br /> dilution factor (smallest <br /> Z sample volume) used for the test and reported with the qualifier code.; <br /> Contract Colonies on plate too numerous to count (TNTC). Results shall be reported as the maximum recommended count of typical target <br /> colonies (60 <br /> Requirement CFUAowest volume used x 100 mL). If atypical, non-target, spreading colonies or other interferences occur where typical target <br /> organisms <br /> cannot be determined, report "No Result" in the results column and "Z" in the Data Oualifter column. <br /> REMAINDER OF PAGE INTENTIONALLY LEFT BLANK <br /> Revision Date: 02/09 <br /> DEP Agreement No, G0353, Attachment J, Page 14 of 14 <br />