My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-089A
CBCC
>
Official Documents
>
2010's
>
2011
>
2011-089A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2016 1:36:26 PM
Creation date
10/1/2015 1:59:46 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
04/12/2011
Control Number
2011-089A
Agenda Item Number
8.J.
Entity Name
Dickerson Florida
Subject
Contract and Specifications
Oslo Road Phase II Roadway Widening
Area
43rd Ave. to 27th Ave.
Project Number
0533
Bid Number
2011018
Supplemental fields
SmeadsoftID
9567
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION NO - 109 - FIELD OFFICE <br /> The Specifications for Field Office ( Contractor) shall include furnishing and installing a Construction Field <br /> Office at or near the Project Limits in accordance with these Specifications . <br /> The Contractor shall maintain , in good condition , for use by the Owner, Owner' s representative and <br /> Contractor' s office personnel , the Cumberland Farms building located at the N . E . corner of Oslo Road <br /> and 27th Avenue , which will be used as a field office . <br /> It is the Contractor' s responsibility to clean the inside of the building and provide furnishings . The building <br /> shall be equipped with tables and chairs for the use of minimum four (4 ) people and shall have sufficient <br /> drawers for the standard size plans , either attached to the tables or in cabinet form , one ( 1 ) rough plan <br /> rack , one ( 1 ) supply cabinet , a minimum of five ( 5 ) gallons of potable water maintained by the Contractor, <br /> one ( 1 ) dual cassette telephone answering machine , one ( 1 ) fax machine , and one ( 1 ) fire- resistant ( 2 ) <br /> drawer legal size file cabinet meeting fire underwriters ' approval for no less than a 1 -hour test . The room <br /> also shall be provided with a desk and chair. <br /> The Contractorwill be required to transfer the utilities out of the County' s name and into the Contractor' s <br /> name . The Contractor will also provide phone lines and internet services for County inspectors . <br /> The field office shall be ready for use no later than ten ( 10 ) calendar days after the date of mailing the <br /> fully executed Contract and before any other work is started , and shall be maintained by the Contractor <br /> until one ( 1 ) month after final acceptance of the Project by the Owner. <br /> See Section 01009 ( Special Provisions ) of the General Requirements . <br /> Item of Payment <br /> Payment shall be made under : <br /> Bid Item No . 109 - 71 - Field Office — Per Lump Sum <br /> SECTION NO - 110 - CLEARING AND GRUBBING <br /> The work specified in this item shall conform to Section 110 of the Florida Department of <br /> Transportation Standard Specifications for Road and Bridge Construction . ( 2010 ) with the <br /> following modifications : <br /> A . Prior to any clearing and grubbing , the contractor will stake the right-of-way . <br /> Unimproved areas shall be cleared of trees , logs , stumps , brush , vegetation , rubbish <br /> and other perishable or objectionable matter within limits shown on the plans excepting <br /> for certain trees and shrubs shown on the plans or as directed by the Engineer which <br /> are to remain undisturbed and protected . Stumps and roots between slope stakes in <br /> cuts and in embankments 3 feet or less in depth shall be removed to a depth of 18 <br /> inches below subgrade . No stumps , roots , or perishable matter of any description shall <br /> remain under concrete slabs or footing , including pavement and sidewalks . <br /> B . No trees shall be removed or relocated until the Engineer or his representative has <br /> marked all trees to be saved , after a review of the project site with the Contractor' s <br /> representative . <br /> C . Where the final pavement or structural work will be close to existing trees , the <br /> Contractor shall exercise care in the vicinity of the trees . Further , the Contractor shall <br /> saw cut along the edge of the outside limits of the stabilization , structure subgrade or <br /> sidewalk to a minimum depth of 4 feet below the finish grade and paint with a <br /> commercial grade pruning paint the ends of all sawn roots . If directed by the Engineer <br /> 01025- 19 Technical Specifications <br /> F -\ Piihlir 1A1nrkc\ FNr, INFFPI N ('" Ill\/ i .czin i PP (I. IF (:TC\ nriZ '2_rlcln PH Phnca 11 ldRrrl Awo to 97th Ava1\ Arimim\ hirl rinrmm � <br />nfc\Tnrhnir� l <br />
The URL can be used to link to this page
Your browser does not support the video tag.