Laserfiche WebLink
' SECTION 00454 on Sworn Statement Under the Florida Trench Safety Act <br /> THIS FORM MUST BE SIGNED BY THE BIDDER WHO WILL BE RESPONSIBLE <br /> FOR THE EXCAVATION WORK (" BIDDER"), OR ITS AUTHORIZED <br /> REPRESENTATIVE, IN THE PRESENCE OF A NOTARY PUBLIC AUTHORIZED TO <br /> ADMINISTER OATHS , <br /> 1 . This Sworn Statement is submitted with Project No. 0545 & 0370 for 66th Avenue <br /> Roadway Improvements (S . R. 60 to North of 49th Street) ONE <br /> 2. This Sworn Statement is submitted by Dickerson Florida , Inc . <br /> (Legal Name of Entity Submitting Swom Statement) <br /> 1 hereinafter " BIDDER" . The BIDDER'S address is _ <br /> 3122 N . 25th St . , Ft . Pierce , FL 34946 <br /> BIDDER's Federal Employer Identification Number (FEIN) is 56 - 1327509 <br /> 3 . My name is Larry To Dale and my relationship to the BIDDER <br /> Pres1denit Name of Individual Signing) <br /> is <br /> (Position or Title) <br /> I certify, through my signature at the end of this Sworn Statement, that I am an <br /> authorized representative of the BIDDER . <br /> 4 . The Trench Safety Standards that will be in effect during the construction of this Project <br /> are contained within the Trench Safety Act, Section 553 . 60 et. seta . Florida Statutes and <br /> refer to the applicable Florida Statue(s) and/or OSHA Regulation(s) and include the <br /> "effective date" in the citation(s) . Reference to and compliance with the applicable <br /> Florida Statute(s) and OSHA Regulation(s) is the complete and sole responsibility of the <br /> BIDDER . Such reference will not be checked by OWNER or ENGINEER and they shall <br /> ' have no responsibility to review or check the BIDDER's compliance with the Trench <br /> Safety Standards, <br /> 5 . The BIDDER assures the OWNER that it will comply with the applicable Trench Safety <br /> Standards. i�r D,6 . The BIDDER <br /> has allocated and included in its bid the total amount of $ , <br /> based on the linear feet of trench to be excavated over five (5) feet deep, or compliance <br /> with the applicable Trench Safety Standards , and intends to comply with said tan p[ds <br /> by instituting the following specific method(s) of compliance on this Project:-. ! <br /> 75e2 adc 14 <br /> The determination of the appropriate method(s) of compliance is the complete and sole <br /> responsibility of the BIDDER. Such methods will not be checked by the OWNER or <br /> ENGINEER for accuracy, completeness, or any other purpose . The OWNER and <br /> O ENGINEER shall have no responsibility to review or check the BIDDER's compliance <br /> with the Trench Safety Standards. OD . <br /> 7 . The BIDDER has allocated and included in its bid the total amount of $ <br /> ' based on the square feet of shoring to be used for compliance with shoring safety <br /> requirements and intends to comply with said shoring requirem is by institute g the <br /> following specific method(s) of compliance on this Project: _ T n j _ m Q� <br /> 00454 - Florida Trench Safety Act - REV 04-07.doc <br /> 00454 - 1 <br /> F:"Ic WorkslENGINEERING DIVISION PROJECTSIM45mMM Ave SR60 to 57th St (AreaditpAdrrAWA3d 0=rrants 0454 - Florida Trach Safety Act . REV 040740o <br />