Laserfiche WebLink
Exhibit 'B" <br />Deliverables <br />FM# 425883-1-58-01 <br />Item No. <br />580-1-2H <br />590-70 <br />Description <br />Quantity <br />Unit <br />BALD CYPRUS (7G, 5' OA) <br />19 <br />EA <br />IRRIGATION SYSTEM, COMPLETE (INCLUDES WELL, PUMPS, <br />ELECTRICAL SERVICE CONDUIT, SPRINKLERS, ETC.) <br />1 <br />LS <br />ROADWAY IMPROVEMENTS <br />PROPOSED BRIDGES & RETAINING/BARRIER WALL <br />26TH STREET RETAINING/BARRIER WALL <br />110-3 <br />455-133-3 <br />460-70-2 <br />521-5-4 <br />DEMOLITION <br />1 <br />LS <br />STEEL SHEETING (AZ -18 - 22'-0" LONG) INCLUDES STEEL SUPPORT <br />PLATES <br />ALUMINUM PEDESTRIAN/BICYCLE BARRIER RAILING <br />521-6-3 <br />544-75-14 <br />7,304 <br />SF <br />332 <br />LF <br />CONCRETE TRAFFIC RAILING BARRIER - (32" VERTICAL SHAPE) <br />WALL COPING WITH TRAFFIC RAILING/RAISED SIDEWALK <br />CRASH CUSHION VEHICLE ATTENUATOR <br />332 <br />LF <br />332 <br />LF <br />1 <br />EA <br />26TH STREET RETAINING/BARRIER WALL <br />33RD STREET BRIDGE <br />110-3 <br />DEMOLITION AND REMOVAL OF EXISTING BRIDGE <br />SUPERSTRUCTURE <br />1 <br />LS <br />400-2-4 <br />41514 <br />CLASS II CONCRETE (FOR CLOSURE POURS BETWEEN DECK UNITS) <br />450-88-18A <br />450-88-18B <br />460-70-2 <br />521-5-1 <br />REINFORCING STEEL (FOR CLOSURE POURS BETWEEN DECK <br />UNITS) <br />PRESTRESSED PRECAST DECK UNITS (18" X 4'-3" X 36'-01 (12 <br />REQUIRED) <br />PRESTRESSED PRECAST DECK UNITS (18" X 4'-6" X 36'-0") (2 <br />REQUIRED) <br />ALUMINUM PEDESTRIAN/BICYCLE BARRIER RAILING <br />521-5-4 <br />13 <br />CY <br />990 <br />LB <br />432 <br />LF <br />72 <br />LF <br />74 <br />LF <br />CONCRETE TRAFFIC RAILING BARRIER - (32" F SHAPE) <br />521-72-3 <br />37 <br />LF <br />CONCRETE TRAFFIC RAILING BARRIER - (32" VERTICAL SHAPE) <br />SHOULDER CONCRETE BARRIER WALL (INDEX 410 - CANTILEVERED <br />WALL) <br />37 <br />LF <br />33.58 <br />LF <br />Page 7 <br />400-2-5 <br />CLASS <br />II <br />CONCRETE <br />(FOR <br />PILES CAPS) <br />78.5 <br />CY <br />415-1-5 <br />REINFORCING <br />STEEL <br />(FOR <br />PILES <br />CAPS) <br />12,090 <br />LB <br />PRESTRESSED <br />PILES <br />455-133-2 <br />18" sq <br />X 65'-0" MINIMUM <br />(TEST PILE - ABUTMENT) <br />(1 EA) <br />65 <br />LF <br />455-34-2A <br />18" sq <br />X 50'-0" MINIMUM <br />(ABUTMENT) <br />(19 EA) <br />950 <br />LF <br />455-34-2B <br />14" sq X 40'-0" MINIMUM <br />(WING BENT) <br />(13 EA) <br />520 <br />LF <br />455-14-5A <br />8" X 8'-0" X 17-0" <br />PRECAST <br />CONCRETE <br />SHEET <br />WALL <br />(26 <br />EA) <br />312 <br />LF <br />Page 7 <br />