My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-194.B
CBCC
>
Official Documents
>
2010's
>
2010
>
2010-194.B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2016 3:45:47 PM
Creation date
10/1/2015 2:23:20 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Agreement
Approved Date
08/17/2010
Control Number
2010-194.B
Agenda Item Number
12.J.1.
Entity Name
Florida Power & Light
Subject
Underground Distribution Facilities Installation
Area
North County RO Water Treatment Plant Well
Supplemental fields
SmeadsoftID
9755
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
" Exhibit A" UCO TARIFF ESTIMATE LCD Tariff Effective: <br /> 1111312008 WR # : �. .r �� - .' 3892146" - - <br /> PROJECT: DATE: 7/9/2010 <br /> DESIGNER LOCATION: • - ' <br /> # OF UNITS # OF UNITS <br /> ( 13.212.x) Primary lateral riser if from overhead termination <br /> point),pintj padmounted transformer and trench with cable-in-conduit CHARGES CREDi75 <br /> not to exceed 150 feet for radials and 300 feet for loops. <br /> (13.2. 12.a. 1 ) Single Phase Radial <br /> From Overhead Termination Point From Existing Underground Termination Point(13.2. 12.a.2) Two Phase Radial $944.87 <br /> X <br /> $2,258.62 X q -ty N/A Use Loop Price X - qty $ <br /> (13.2. 12.x.3) Three Phase Radial - 150KVA $885 .6 X qty N/A Use Loop Price X qty <br /> (13.2.12.a.4) Three Phase Radial - 300 KVA qty NIA Use Loop Price X qty <br /> (13.2.12.a .6) Two Phase Loop <br /> ( 13.2.12.a .5) Single Phase loop $0.00 X - qty NIA Use Loop Price X <br /> $4,562.43 X <br /> $2,394.99 X qty $1 ,316.90 X qty $ <br /> $6,236.31 X qty $ <br /> - <br /> (13.2.12.a.7) Three Phase Loop - 150 KVA ` qty $3,125.06 X qty $ <br /> (13.2. 12.x.7) Three Phase Loop - 300 KVA $3,135.99 X qty $4,738.19 X ; ��� � qty $ <br /> qty $1 ,820.03 qty S <br /> ( 13.2.12.b) Secondary riser and lateral, excluding handhole or junction box, with connection to Applicant's service cables <br /> no greater than 20 feet from Company riser pole. <br /> (13.2.12.b.1 ) Small Single Phase 410 TPX or smaller $513.28 X :...: . <br /> (13.2.12. b.2) Large Single Phase larger than 410 TPX per riser $ <br /> 5 ,333.8 X per riser <br /> ( 13.2.12. b.3) Small Three Phase 4/0 OPX or smaller 8705 gg X , <br /> (13.2. 12.b.4) Large Three Phase larger than 410 OPX Per riser $ <br /> $1 ,333.83 X ^ .. per riser $ <br /> 9 <br /> It 3.2.12.c) Small UG commercial services (60 Amp 120V / 125 Amp 120/240V per SPO 21010.4) <br /> ( 13.2.12.c.t .a) 2 wire (120V) service on accessible wood pole $596.66 X <br /> (13.2.12.c.1 .b) 3 wire (1201240V) service on accessible wood pole $615.89 X , per service $ <br /> ( 13.2.12.c.2.a ) 2 wire (120V) service on inaccessible wood pole $676.85 X per service $ <br /> (13.2.12.c.2.b) 3 wire ( 1201240V) service on inaccessible wood pole $698.19 X per service $ - <br /> per service - <br /> (13.2. 12.c.3.a) 2 wire (120V) service on accessible concrete pole $617.79 X � � �- - � - $ - <br /> (13.2. 12.c.3.b) 3 wire (120/240V) service on accessible concrete pole $637.00 X Per service $ <br /> : �: ::r : ,. .. . per service $ - <br /> (13.2.12.d) Handholes and Padmounted Secondary Junction Boxes, excluding connections. <br /> (13.2. 12.d.1 ) Handholes <br /> ( 13.2. 12.d.1 .a) Small 24" handhole $178.76 X , per HH <br /> ( 13.2.12.d.t .b) Intermediate 30" handhole $207.95 X - $ - <br /> ( 13.2.12.d.1 .c) Large 48" handhole per HH $ <br /> $725.72 X per <br /> (13.2.12.d.2) Pad Mounted Junction Box (PM TX Dummy $1 ,582.71 X ��. : �� per box $ <br /> Cabinet M&S #161 -40000-7) $ _ <br /> (13.2.12.d.3.a) Pad Mounted Junction Cabinet (22 port $11 ,477.44 X _Jper cabinet <br /> 3 phase cabinet M&S #161 -40100-3) <br /> (13.2.12.d.3.b) Tapping conductors (if more than 12 sets) $64.48 X per set <br /> (13.2.12.e) Primary Splice Box including splices and cable pulling set-up <br /> ( 13.2.12.e.1 ) Single Phase per box $1 ,253.76 X per box <br /> (13.2.12.e.2) Two Phase per box $1 ,763.18 % $ <br /> ( 13.2.12.e.3) Three Phase per box per box $ <br /> $1 ,938.57 X per box $ <br /> (13.2.12.f) Additional installation charge for underground primary laterals including trench and cable-in-conduit which exceeds <br /> the limits set in 13.2.12.a to reach FPL designated point of delivery. <br /> ( 13,2.12J.1 ) Single Phase per foot $1 .33 X I perft. <br /> (13.2.12.f.2) Two Phase per foot $3.12 X8 <br /> (13.2. 12.(.3) Three Phase per foot per ft. $ <br /> $3.35 % 590 per ft. E 1 ,976.50 <br /> (13.2.12.g) Additional installation charge for underground primary laterals including trench and cable-in-conduit extended <br /> beyond the FPL designated point of delivery. <br /> ( 13.2.12.g.1 ) Single Phase per foot 87.30 X per ft. <br /> (I 3.2. 12.9.2 ) Two Phase per foot <br /> (I 3.2.12.g.3) Three Phase per foot $ 10'88 X per ft. $ <br /> 812.91 X per ft. $ <br /> (13.2.12.h) UG Feeder $ <br /> ( 13 2.12.h) 1000 KCMIL (not including switch package) $ 12. 89 X <br /> per ft. <br /> ( 13.2.12.h) Switch package (9/3 per package) $21 ,315.92X <br /> ( 13.2.12.h) Switch package (616 per package) each ++ 1 <br /> $21 ,315.92 X � - each ` ' <br /> . ..._,. <br /> (13.2.13.x ) Trench and backfilling credits 4P <br /> y <br /> (13.2.13.x.1 ) Credit per foot of primary trench $ 2.83 X : 740 . per ft. <br /> (13.2.13.x.2) Credit per foot of secondary trench 82.63 X Per ft. .w. �.1 " , '# t, ; 'i , ` $ -'1 <br />2A94.20 <br /> Y_ <br /> (13.2. 13.b) Conduit installation credits STATE OF FLORIpC= :r�'� - • � d + "` <br /> INDIAN RIVER COU Ul <br /> It } 5 j <br /> 3.2.13.b.1 ) Credit per foot of 2" PVC $0.49 X d! • �, b ' • . c <br /> ( 13.2.13.b.2) Credit per toot of 5" PVC per it. <br /> $os9 x 740 per n. THIS I3 TOCERTIFY TipTTTTTTTTT� jg $ <br /> A TRUE AND CDRREC-Y(7!Qp F S"•503.20 <br /> ( 13.2. 13.c) Handhale / primary splice box installation credits THE ORIGINAL ON RILFLa <br /> ( 13.2.13.c.1 ) Credit per large HH (greater than 30") / Pri Splice Box $189. 11 XHH s OFFICE r /', / 3 <br /> ( 13.2.13.x2) Credit per small I intermediate HH (30" or less) $49.71 % 1, 1 w ,�! r "'� k l <br /> HH(s) EF REY K. RT ` � 1 ` ` ' • ` � s <br /> ( 13.2.13.d) Transformer I cap bank pad installation credits <br /> By C <br /> ( 13.2. 13.d.) Credit per pad 829. 24 X pad(s) . <br /> DATE a � 0 <br /> Feeder Splice Box Credit (FDRSPLICEBOX-07.860) 5717.45 X each <br /> Padmount Switch Chamber Credit (FDRSWPAD-07-860) $459. 13 X <br /> each $ <br /> Additional Charges (e.g. non-rapid trenching, restoration, etc.) <br /> TOTAL CONTRIBUTION: $ 2 862. 11 <br /> LESS TOTAL CREDITS: $ 2,626.64 <br /> TOTAL CASH PAYMENT: $ 235.47 <br /> TOTAL CUSTOMER PAYMENT $ 2 882, 11 <br /> (CONTRIBUTION MAT + LABOR) $ 2 626.64 <br /> ersrzeto 1 :18 PM (CONTRIBUTION CASH) <br />
The URL can be used to link to this page
Your browser does not support the video tag.