346 PORTLAND CEMENT CONCRETE . <br /> (REV 6-940) (FA 64840) (141 ) <br /> SUBARTICLE 346 -3 . 1 (Pages 320 — 321 ) is deleted and the following substituted : ov <br /> 346-3 . 1 General : The separate classifications of concrete covered by this Section are <br /> designated as Class I, Class II, Class III, Class IV , Class V and Class VI . Strength, slump , and air <br /> content of each class are specified in Table 2 . <br /> Substitution of a higher class concrete in lieu of a lower class concrete may be <br /> allowed, if approved by the Engineer. When the compressive strength acceptance data is less <br /> than the minimum compressive strength of the higher design mix, notify the Engineer. <br /> Acceptance is based on the requirements in Table 2 for the lower class concrete . <br /> TABLE 2 <br /> Class of Specified Minimum Strength Target Slump Value Air Content <br /> Concrete (28 -day) (psi) (inches) (c) Range (%) <br /> STRUCTURAL CONCRETE <br /> I (a) 35000 3 (b) 1 . 0 to 6 . 0 <br /> I (Pavement) 300 2 1 . 0 to 6 . 0 <br /> II (a) 3 ,400 3 (b) 1 . 0 to 6 . 0 <br /> II (Bridge 4 ) 500 3 (b) 1 . 0 to 6 . 0 <br /> Deck) <br /> III ( e) 5 , 000 3 (b) 1 . 0 to 6 . 0 <br /> III (Seal) 3 , 000 8 1 . 0 to 6 . 0 <br /> IV 5 , 500 3 (b) (d) 1 . 0 to 6 . 0 <br /> IV (Drilled 4 , 000 8 . 5 0 . 0 to 6 . 0 <br /> Shaft) <br /> V ( Special) 6 , 000 3 (b) (d) 1 . 0 to 5 . 0 <br /> V 6 , 500 3 (b) (d) 1 . 0 to 5 . 0 <br /> VI 8 , 500 3 (b) (d) 1 . 0 to 5 . 0 <br /> (a) For precast three sided culverts , box culverts , endwalls , inlets , <br /> manholes and junction boxes , the target slump value and air content will not apply. The <br /> maximum allowable slump is6 inches , except as noted in (b) . The Contractor is permitted to use <br /> concrete meeting the requirements of ASTM C 478 4 , 000 psi in lieu of Class I or Class II <br /> concrete for precast endwalls , inlets , manholes and junction boxes . <br /> (b) The Engineer may allow a higher target slump when a Type F , G, I or <br /> II admixture is used, except when flowing concrete is used . The maximum target slump shall be <br /> 7 inches . <br /> (c) For a reduction in the target slump for slip -form operations , submit a <br /> revision to the mix design to the Engineer. <br /> - 117 - <br /> FPID ( S ) : 423186 - 1 - 58 - 01 <br /> l <br />