Laserfiche WebLink
b <br /> Use signs with specific business names on each sign . Install logos provided by <br /> business owners and approved by the Engineer. Standard Business entrance signs meeting the <br /> requirements of Index 17355 without specific business names may be used only with the <br /> approval of the Engineer. <br /> 102-9 .4 High Intensity Flashing Lights : Furnish Type B lights in accordance with the <br /> plans and Design Standards . <br /> 102-9 .5 Warning/Channelizing Devices : Furnish warning/channelizing devices in <br /> accordance with the plans and Design Standards . <br /> 102-9 . 5 . 1 Retroreflective Collars for Traffic Cones : Use collars for traffic <br /> cones listed on the QPL that meet the requirements of Section 990 . Use cone collars at night <br /> designed to properly fit the taper of the cone when installed. Place the upper 6 inches collar a <br /> uniform 3 1 /2 inch distance from the top of the cone and the lower 4 inch collar a uniform 2 inch <br /> distance below the bottom of the upper 6 inch collar. Ensure that the collars are capable of being <br /> removed for temporary use or attached permanently to the cone in accordance with the <br /> manufacturer' s recommendations . Provide a white sheeting having a smooth outer surface and <br /> that has the property of a retroreflector over its entire surface . <br /> 102-9 . 5 .2 Barrier Wall (Temporary) : Furnish, install, maintain, remove and <br /> relocate a temporary barrier wall in accordance with the plans . Ensure that temporary concrete <br /> barrier wall for use on roadway sections , complies with Index No . 412 , 415 or 414 as specified in <br /> the plans . Ensure that temporary concrete barrier wall for use on bridge and wall sections , <br /> complies with Index No . 414 as specified in the plans . Ensure that temporary water filled barrier <br /> wall used on roadway sections meets the NCHRP Report 350 criteria or the MASH and is listed <br /> on the Qualified Products List (QPL) . Barriers meeting the requirements of Index No . 41 2 , 415 <br /> or temporary water filled barriers on the QPL will not be accepted as an alternate to barriers <br /> meeting the requirements of Index No . 414 . <br /> 102-9 . 5 .3 Glare Screen (Temporary) : Use temporary glare screens listed on the <br /> QPL that meet the requirements of Section 990 . Furnish, install, maintain, remove and relocate <br /> glare screen systems in conjunction with temporary barrier wall at locations identified in the <br /> plans . <br /> Ensure the anchorage of the glare screen to the barrier is capable of safely <br /> resisting an equivalent tensile load of 600 lb/ft of glare screen, with a requirement to use a <br /> minimum of three fasteners per barrier section . <br /> When glare screen is utilized on temporary barrier wall , warning lights <br /> will not be required. <br /> 102 -9 . 6 Temporary Crash Cushion (Redirect/Inertia) : Furnish , install , maintain and <br /> subsequently remove temporary crash cushions in accordance with the details and notes shown <br /> in the plans , the Design Standards , and requirements of the pre - approved alternatives listed on <br /> the QPL. Maintain the crash cushions until their authorized removal . Repair all attachment scars <br /> to permanent structures and pavements after crash cushion removal . Make necessary repairs due <br /> to defective material , work, or Contractor operations at no cost to the Department . Restore crash <br /> cushions damaged by the traveling public within 24 hours after notification as authorized by the <br /> Engineer. <br /> 102-9 .7 Guardrail (Temporary) : Furnish guardrail (temporary) in accordance with the <br /> plans and Design Standards . Meet the requirements of Section 536 . <br /> - 29 - <br /> FPID (S ) : 423186 - 1 - 58 - 01 <br />