Official Document Type
Contract
Approved Date
11/01/2011
Control Number
2011-226B.1
Agenda Item Number
8.N.
Entity Name
Goodson Paving
Subject
Contract and Specifications Old Dixie Sidewalk
Volume II
Area
Old Dixie Highway from 38th Lane to 65th St.
Project Number
0845
Bid Number
2011045
Supplemental fields
SmeadsoftID
10419
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
requirements of Sections 11 . 1 and 11 . 2 of the Department ' s Materials Manual , which may be <br /> viewed at the following URLs : <br /> www dot state . fl . us/specificationsoffice/Implemented/URLinSpecs/Files/sectionl I l . pdf . <br /> www dot state fl us/specificationsoffice/hnplementediURLinSpecs/Files/sectionl 12 . pdf . <br /> SUBARTICLE 105 - 5 . 2 . 1 (Page 140) is deleted and the following substituted : <br /> 105-5 .2 . 1 Qualifications : Submit the Training Identification Numbers (TINS) or <br /> any other information which will be traceable to the certification agency ' s training location and <br /> dates for all technicians performing sampling, testing and inspection for both field and laboratory <br /> tests . Provide the names of the CTQP certifications and other pertinent certifications held and the <br /> expiration dates for each certification for each technician . Include employed and subcontracted <br /> technicians . <br /> ARTICLE 105 - 6 (Page 142) is deleted and the following substituted : <br /> 105-6 Lab Qualification Program. <br /> Testing Laboratories participating in the Department ' s Acceptance Program must have <br /> current Department qualification when testing materials that are used on Department projects . In <br /> addition, they must have one of the following : <br /> a . Current AASHTO (AAP) accreditation . <br /> b . Inspected on a regular basis per ASTM D 3740 for earthwork, ASTM D 3666 <br /> for asphalt and ASTM C 1077 for concrete for test methods used in the Acceptance Program, <br /> with all deficiencies corrected, and under the supervision of a Specialty Engineer. <br /> c . Current Construction Materials Engineering Council (CMEC) program <br /> accreditation or other independent inspection program accreditation acceptable to the Engineer <br /> and equivalent to a. or b . above . <br /> After meeting the criteria described above , submit a Laboratory Qualification Application <br /> to the Department. The application is available from the Department ' s website . Obtain the <br /> Department ' s qualification prior to beginning testing . The Department may inspect the <br /> laboratory for compliance with the accreditation requirements prior to issuing qualification . <br /> Meet and maintain the qualification requirements at all times . Testing without <br /> Department ' s qualification may result in a rejection of the test results . Continued qualifications <br /> are subject to satisfactory results from Department evaluations , including Independent Assurance <br /> evaluations . In case of suspension or disqualification, prior to resumption of testing , resolve the <br /> issues to the Department ' s satisfaction and obtain reinstatement of qualification . The following <br /> conditions may result in suspension of a laboratory ' s qualified status : <br /> a. Failure to timely supply required information. <br /> b . Loss of accredited status . <br /> c . Failure to correct deficiencies in a timely manner . <br /> d. Unsatisfactory performance . <br /> e . Changing the laboratory ' s physical location without notification to the <br /> accrediting agency and the Engineer. <br /> f. Delays in reporting the test data in the Department ' s database . <br /> g . Incomplete or inaccurate reporting . <br /> -45 - <br /> FPID ( S ) : 423186 - 1 - 58 - 01 <br />