My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-056A
CBCC
>
Official Documents
>
2010's
>
2012
>
2012-056A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2015 2:00:06 PM
Creation date
10/1/2015 4:19:34 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
04/03/2012
Control Number
2012-056A
Agenda Item Number
8.K.
Entity Name
Guettler Brothers
Subject
66th Avenue Roadway Improvements Phase 2
Area
4th Street to 16th St.
Project Number
9810-B
Bid Number
2012032
Archived Roll/Disk#
112-R-0001
Supplemental fields
SmeadsoftID
11108
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLARIFICATIONS / CORRECTIONS/ QUESTIONS : <br /> 1 . All fill material placed in the road right- of-way shall meet AASHTO Soil Classification A-3 <br /> with a <br /> maximum of 10% passing the 0 . 075 (200 ) sieve . <br /> 2 . REVISED Plan Sheets 10 and 11 - Revised quantities per various revisions . <br /> 3 . REVISED Plan Sheet 12 - Revised S -96 per plan revisions . <br /> 4. REVISED Plan Sheet 14 - Revised EW- 23 per plan revisions . <br /> 5 . REVISED Plan Sheet 14A - Added EW-28 per plan revisions <br /> 6 . REVISED Plan Sheet 23 - Show jumper and added note per FDEP . <br /> 7 . REVISED Sheet 49 — Added RIPRAP SAND CEMENT ENDWALL at Station 90+ 20 left, REVISE Line <br /> Item 5304 RIPRAP SAND CEMENT ENDWALL Quantity 92, Unit CY is amended to read 530- 1 <br /> RIPRAP SAND CEMENT ENDWALL Quantity 103 , Unit CY <br /> 8 . REVISED Sheet 58 — Installing an additional 70 feet of 72" RCP from Station 28 +05 to Station <br /> 28+75, REVISE Line Item 430475405, 72" REINFORCED CONCRETE PIPE, Quantity 781 , Unit LF is <br /> amended to read 430475405 , 72 " REINFORCED CONCRETE PIPE, Quantity 849, Unit LF . This line <br /> item shall include the removal of the existing 54" CMP and restoration of the dirt driveway within <br /> the limits of this pipe extension . The Riprap Sand Cement Endwall shall be moved to the end of <br /> the pipe . <br /> 9 . Line Item 3394 ASPHALT PAVEMENT MISCELLANEOUS ( 2" THICK UNDER GUARDRAIL), QUANTITY <br /> 989, Unit SY is amended to read 3394 ASPHALT PAVEMENT MISCELLANEOUS ( 3 " THICK UNDER <br /> GUARD RAIL), QUANTITY - 150, Unit — TON . <br /> 10 . Question : Will there be a line item added to the bid schedule for the Littoral Zone Planting and <br /> Maintenance shown on Sheet 153 of the plans ? If not, do we include that in the landscape bid <br /> items? <br /> Answer : The Littoral Zone Planting and Maintenance shown on Sheet 153 of the plans shall be <br /> included in line Item (580-1 - LANDSCAPING COMPLETE (SMALL PLANTS LESS THAN 7 GAL) (SEE <br /> PLAN FOR QUANTITIES), QUANTITY - 1, Unit — LS ) and Line Item (580-2 - LANDSCAPING <br /> COMPLETE (SMALL PLANTS GREATER THAN 7 GAL) (SEE PLAN FOR QUANTITIES ), QUANTITY - 11 <br /> Unit — LS ) <br /> 11 . Question : The plans call for 2" x 2" and 1 . 75" x 1 . 75" galvanized posts . Are these posts u-channel <br /> or square tube ? If they are u -channel , do the plans mean 2# u -channel and if square tube could <br /> you let me know where I could procure these materials ? <br /> Answer : All posts are square tube . The County has used Ft . Pierce Universal Signs and Accessories <br /> in the past . However there are other suppliers available . <br /> 12 . Question : Are the sign posts required to be 12, 14, or 16 gauge steel ? <br /> Answer: All posts are required to be minimum 12 gauge steel . <br /> Page 2 of 5 RAPublicWorkAENGINEERINGDIVISION PROIECM98108-66th <br /> Ave Ph 24th St to 16th StVdmimWDENDUMSVddendum No. 3, 3-5.11.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.