My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-204A
CBCC
>
Official Documents
>
2010's
>
2011
>
2011-204A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/19/2019 12:07:28 PM
Creation date
10/1/2015 2:53:55 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
09/13/2011
Control Number
2011-204A
Agenda Item Number
12.I.1
Entity Name
Timothy Rose Contracting
Subject
Intersection Improvements Indian River Boulevard
Area
Indian River Boulevard and 17th St.
Project Number
1024
Bid Number
2011048
Supplemental fields
SmeadsoftID
10258
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
120-8.1.6 Placement and Compaction: Place the material in horizontal layers <br />not exceeding 6 inches compacted thickness, in depth above water level, behind abutments, <br />wingwalls and end bents or end rest piers, and around box culverts and all structures <br />including pipe culverts. When the backfill material is deposited in water, compact per 120- <br />8.2.5 and 120-8.3.4. <br />The Contractor may elect to place material in thicker lifts of no <br />more than 12 inches compacted thickness outside the soil envelope if he can demonstrate <br />with a successful test section that density can be achieved. Notify the Engineer prior to <br />beginning construction of a test section. Construct a test section of 500 feet in length. Perform <br />five tests at random locations within the test section. All five tests must meet the density <br />required by 120-7.2. Identify the test section with the compaction effort and soil classification <br />in the Agency Logbook. In case of a change in compaction effort or soil classification, <br />construct a new test section. When a test fails the requirements of 120-7.2, construct a new <br />test section. The Contractor may elect to place material in 6 inches compacted thickness at <br />any time. <br />120-8.2 Additional Requirements for Structures Other than Pipe: <br />120-8.2.1 Density: Where the backfill material is deposited in water, obtain a <br />12 inch layer of comparatively dry material, thoroughly compacted by tamping, before <br />verifying the layer and density requirements. Meet the requirements of the density Acceptance <br />Criteria. <br />120-8.2.2 Box Culverts: For box culverts over which pavement is to be <br />constructed, compact around the structure to an elevation not less than 12 inches above the <br />top of the structure, using rapid -striking mechanical tampers. <br />120-8.2.3 Other Limited Areas: Compact in other limited areas using <br />mechanical tampers or approved hand tampers, until the cover over the structure is at least <br />12 inches thick. When hand tampers are used, deposit the materials in layers not more than <br />4 inches thick using hand tampers suitable for this purpose with a face area of not more than <br />100 in2. Take special precautions to prevent any wedging action against the masonry, and <br />step or terrace the slope bounding the excavation for abutments and wingwalls if required by <br />the Engineer. <br />120-8.2.4 Culverts and Piers: Backfill around culverts and piers on both sides <br />simultaneously to approximately the same elevation. <br />120-8.2.5 Compaction Under Wet Conditions: Where wet conditions do not <br />permit the use of mechanical tampers, compact using hand tampers. Use only A-3 material <br />for the hand tamped portions of the backfill. When the backfill has reached an elevation and <br />condition such as to make the use of the mechanical tampers practical, perform mechanical <br />tamping in such manner and to such extent as to transfer the compaction force into the <br />sections previously tamped by hand. <br />120-8.3 Additional Requirements for Pipe 15 Inches Inside Diameter or <br />Greater: <br />120-8.3.1 General: Trenches for pipe may have up to four zones that must be <br />backfilled. <br />Lowest Zone: The lowest zone is backfilled for deep undercuts up to <br />within 4 inches of the bottom of the pipe. <br />Bedding Zone: The zone above the Lowest Zone is the Bedding Zone. <br />Usually it will be the backfill which is the 4 inches of soil below the bottom of the pipe. When <br />rock or other hard material has been removed to place the pipe, the Bedding Zone will be the <br />12 inches of soil below the bottom of the pipe. <br />01025-27 Technical Specifications <br />F:\Public Works\ENGINEERING DIVISION PROJECTS\1024-17thStreet and IR Blvd Intersection\AdmimlContract Documents\Technical <br />Specifications.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.