My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-020
CBCC
>
Official Documents
>
2010's
>
2011
>
2011-020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2016 11:28:02 AM
Creation date
10/1/2015 1:44:20 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Bid
Approved Date
02/01/2011
Control Number
2011-020
Agenda Item Number
8.H.
Entity Name
Electrical Contracting Service Inc.
Vero Beach Sports Village
Subject
Bid Award Lighting System County Funding Project
Area
Vero Beach Sports Village
Project Number
1042
Bid Number
2011025
Alternate Name
Dodgertown
Supplemental fields
SmeadsoftID
9284
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLARIFICATIONS / CORRECTIONS : <br /> The following portions of the Contract Documents are modified as shown below: <br /> 1 . TECHNICAL SPECIFICATIONS <br /> PART 1 - GENERAL <br /> 1 ,1 SUMMARY <br /> Be Scope of Work <br /> 2, cc) DELETE THIS ITEM ENTIRELY AND REPLACE WITH THE FOLLOWING : <br /> cc) Coordinate and pay all fees associated with electrical service connections as required <br /> by City of Vero Beach Utilities, <br /> 1 .2 LIGHTING PERFORMANCE <br /> A . AND Be DELETE BOTH ITEMS ENTIRELY AND REPLACE WITH THE FOLLOWING : <br /> A. PERFORMANCE REQUIREMENTS: PLAYING SURFACES SHALL BE LIT TO AN AVERAGE MAINTAINED LIGHT LEVEL AND <br /> UNIFORMITYAS SPECIFIED IN THE CHARTBELOw. LIGHT LEVELS SHALL BE MAINTAINED FOR 25 YEARS. LIGHTING <br /> CALCULATIONS SHALL BE DEVELOPED AND FIELD MEASUREMENTS TAKEN ON THE GRID SPACING IMTH THE MINIMUM <br /> NUMBER OF GRID POINTS SPECIFIED BELOW. <br /> Average Maximum to Grid Grid <br /> Area of Lighting Maintained Light Minimum Points Spacing <br /> Levels Uniformity Ratio <br /> Baseball Field #1 Infield 100 footcandles 1. 3: 1. 0 25 30 ' x30 ' <br /> Baseball Field #2 Infield 100 footcandles 1.3:1. 0 25 30' x30' <br /> Baseball Field #1 70 footcandles 2.4:1. 0 128 30' x30 ' <br /> Outfield <br /> Baseball Field #2 <br /> Outfield 70 footcandles 2.4: 1. 0 133 30 ' x30 ' <br /> 9. Independent Test Report: Manufacturers bidding any form of light system must provide an <br /> independent test report certifying the system meets the lumen requirements above and verifying <br /> the field performance of the system for the duration of the useful life of the lamp based on lamp <br /> replacement hours. Report shall be signed by a licensed professional engineer with outdoor <br /> lighting experience. <br /> 2. Project References: Manufacturers bidding any form of light system must provide a minimum of <br /> five (5) project references within the state of Florida that have been completed within the last two <br /> (2) calendar years. Manufacturer will Include project name, project city, contact name, and <br /> contact phone number for each reference. <br /> B. Lamps <br /> • All Manufacturers must provide 1500 watt metal halide lamps <br /> O Lamps exceeding 180, 000 Lumens will not be approved. <br /> • Must provide lamp cut sheets <br /> O Initial lumen output of the lamp shall be based upon "lamp manufacturers Initial lumen values <br /> after 100 hours of lamp operation " per ANSI standards. A minimum light loss factor of . 95 <br /> must be used for initial calculations. <br /> Page 2 of 7 <br /> F.• IPubiic WOlkBiENGINEERINGDIVISIONPROJECTM1042 VBSPOMP711aLgeLightinel4dmimlbiddocummisiAddendumslADDENDVMNO l.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.