My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1994-01
CBCC
>
Ordinances
>
1990'S
>
1994
>
1994-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 2:01:02 PM
Creation date
9/30/2015 3:58:20 PM
Metadata
Fields
Template:
Ordinances
Ordinance Number
1994-01
Adopted Date
01/05/1994
Ordinance Type
Land Development Regulations
State Filed Date
01\18\1994
Subject
Land Development Regulations Various Chapters Amendments
Archived Roll/Disk#
2743
Supplemental fields
SmeadsoftID
1073
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(3) Private land clearing debris burning facilities (special <br />=xception). <br />a) Districts requiring special exception approval (pursuant t <br />the provisions of 971.05): A-1, A-21 A-3. <br />(b) Additional information requirements: A site plan meeting all <br />the requirements of Chapter 914, which shows: The locatior <br />and specification of all screening materials; the location anc <br />designation of all thoroughfare roads which serve the site; <br />and occupied structures within five hundred (500) feet of the <br />burn area; the location of proposed stockpiles and the burr <br />areas and all required setbacks. <br />1. There shall be, at minimum, a five hundred -foot <br />separation distance between the burn area of the facility <br />and any occupied structure in existence at the time of <br />the site plan application. <br />The use shall be limited to property with an AG -1. AG -21 <br />or AG -3 land use plan desiqnation. <br />3. The facility shall have direct access to a thoroughfar <br />plan road, or direct access to a non -thoroughfare pla <br />road that has a traffic volume of less than forty (40 <br />trips ends per day. <br />No debris storage or burn area shall be within three <br />hundred (300) feet of any property line. <br />Prior to site plan release the applicant must provide the <br />county a copy of the appropriate Florida Department of <br />Environmental Regulation (FDER) permit or other written <br />approval or letter of no objection from FDER for the <br />proposed project. <br />debris <br />burning <br />facilities. <br />(c) Criteria for land <br />clearing <br />be <br />by the Indian <br />River Count <br />1. There shall be, at minimum, a five hundred -foot <br />separation distance between the burn area of the facility <br />and any occupied structure in existence at the time of <br />the site plan application. <br />The use shall be limited to property with an AG -1. AG -21 <br />or AG -3 land use plan desiqnation. <br />3. The facility shall have direct access to a thoroughfar <br />plan road, or direct access to a non -thoroughfare pla <br />road that has a traffic volume of less than forty (40 <br />trips ends per day. <br />No debris storage or burn area shall be within three <br />hundred (300) feet of any property line. <br />Prior to site plan release the applicant must provide the <br />county a copy of the appropriate Florida Department of <br />Environmental Regulation (FDER) permit or other written <br />approval or letter of no objection from FDER for the <br />proposed project. <br />7. A Type "A" buffer must be provided on all boundarie <br />-abutting residentially used or residentially designate <br />property. <br />The volume of stockpiled land clearing debris on sit <br />shall not exceed the thirty -day burn volume capacity o <br />the incinerator. The site plan application shall; sho <br />how the volume of all stockpile areas on the site:shal <br />be limited to the thirty -day burn volume capacity of th <br />incinerator. <br />9. If any of the debris hauling route(s) associated with <br />facility operation is over county maintained, unpaved <br />roads, the applicant must maintain that section of the <br />hauling route during the debris hauling activity, and <br />security for this purpose may be required, as determined <br />by the county engineer. The provisions of section 934.09 <br />of the county excavation and mining ordinance shall apply <br />to debris hauling activities associated with debris <br />burning facilities, in the same way saidprovisions apply <br />to excavated material hauling activities associated with <br />minina operations. <br />be <br />by the Indian <br />River Count <br />6. The facility <br />must <br />approved <br />Solid <br />Waste Disposal <br />District <br />(SWDD) Board. <br />7. A Type "A" buffer must be provided on all boundarie <br />-abutting residentially used or residentially designate <br />property. <br />The volume of stockpiled land clearing debris on sit <br />shall not exceed the thirty -day burn volume capacity o <br />the incinerator. The site plan application shall; sho <br />how the volume of all stockpile areas on the site:shal <br />be limited to the thirty -day burn volume capacity of th <br />incinerator. <br />9. If any of the debris hauling route(s) associated with <br />facility operation is over county maintained, unpaved <br />roads, the applicant must maintain that section of the <br />hauling route during the debris hauling activity, and <br />security for this purpose may be required, as determined <br />by the county engineer. The provisions of section 934.09 <br />of the county excavation and mining ordinance shall apply <br />to debris hauling activities associated with debris <br />burning facilities, in the same way saidprovisions apply <br />to excavated material hauling activities associated with <br />minina operations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.