2004-006
CBCC
>
Resolutions
>
2000's
>
2004
>
2004-006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2017 4:20:23 PM
Creation date
9/30/2015 4:49:26 PM
Metadata
Fields
Template:
Resolutions
Resolution Number
2004-006
Approved Date
01/06/2004
Agenda Item Number
11.I.5.
Resolution Type
Transportation Memorandum of Agreement
Entity Name
Florida Department of Transportation (FDOT)
Subject
Landscaping and Irrigations Improvements for US1
Area
South Relief Canal to 8th Street
Archived Roll/Disk#
2746
Supplemental fields
SmeadsoftID
2166
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRIC REMOTE CONTROL VALVE BOX!AMETEK.OR£OVAL <br /> VALVE IIRRITROU FINISHED ROADWAY <br /> COVER OF VALVE BOX PLANT MATERIAL <br /> FINISH GRADE <br /> (NEPCD T-1601 GATE VALVE TO BE SANE <br /> EXISTING UTILITY FINISH GRADE/TOP OF MULCH <br /> SIZE AS REMOTE CONTROL VALVE VALVE BOX TO SIT FIRMLY 36'MIN. IN CONFLICT 36'MIN. POP-UP SPRAY SPRINKLER <br /> ON COMPACTED GRAVEL COVER COVER <br /> BASE <br /> 6'LAYER OF COMPACTED .LATERAL PIPE INCHI BARRB ELBOALE W X .490 <br /> COURSE GRAVEL. ADJUST 1 PoLY PIPE <br /> THICKNESS AS NECESSARY 1 18' MIN. <br /> TO ESTABLISH FINISHED <br /> GRADE OF VALVE BOX 1 IRRIGATON PAIN COVER �SCH 40 <br /> OR ELL <br /> OR LATERAL(SEE <br /> PVC MAIN PLAN FOR SIZE1 <br /> TOP OF CUT-OUT TO BE MAX.2' NOTE:IRRIGATION MAIN LINES OR LATERAL LINES THAT ARE SHOWN 112-INCH MALE <br /> GRAVEL OUST EXTEND ABOVE TOP OF PIPE.PLUG AS PVC PIPES IN SLEEVES MAY NEED TO BE SUBTITUTED WITH NPT X AAO INCL <br /> A MINIMUM OF 6'VE BOX BARB ELBOW <br /> EDGES Of VALVE BOX SCH BO REMAINING CUT-WT VOID TO H.D.P.E. PIPE AND DIRECTIONALLY GRILLED WHERE EXISTING � � <br /> PVC PIPE PREVENT WASHING OF SOIL INTO BOX UTILITIES CAN NOT BE CROSSED WITHOUT EXCESSIVE - <br /> EXCAVATION. COORDINATE ALL CHANGES WITH ENGINEER PVC LATERAL PIPE <br /> NOTE:VALVE BOX SHALL BE CAPABLE OF WITHSTANDING A 200 PSF 12" POP-UP SPRINKLER <br /> LOAD WITHOUT BREAKING, TILTING,OR SINKING. TYPICAL CONFLICT DETAIL NOT TO SCALE <br /> NOT TO SCALE _FINISH GRAOEF <br /> CONTROL VALVE W/ GATE VALVE TOP OF MULCH <br /> MOT TO SCALE <br /> POP-UP SPRAY SPRINKLER <br /> - ELECTRIC VALVE - 1/2-INCH MALE NPT X .490 <br /> INCH BARB ELBOW <br /> f`----4ZONE NUMBER - POLY PIPE <br /> �1 <br /> LOCKABLE HANDLE fIBERCLA55 REINFORCED 4 PVC SCH 40TEE OR ELL <br /> ENCLOSURE J'6'L X 4'W X p . <br /> 3'H.!SHOWN IN OPEN POSITION) U <br /> FOREST GREEN GELCOAT FINISH4. GPO - a <br /> 1/2-INCH YALE <br /> RAIN SENSOR PORT VALVE LABEL DETAIL NPT x .490 INCH <br /> KEEP COVER AREA - NOT TO SCALE - BARB ELBOW <br /> CLEAR AND LEVELt � PVC LATERAL PIPE <br /> HINGE,6' THICK REINFORCED 4" POP-UP SPRINKLER <br /> 42'X 48'ALUMINUMSTAINLESS STEEL NOT TO SCALE <br /> - <br /> SKIDCONCRETE PAD <br /> PROVIDED BY PUMP STATION WITH ENCLOSURE <br /> CONTROL PANEL ASSEMBLY HOOVER 3'CHECK VALVE GALV.WELL fL�' N <br /> MAINTAIN 42'CLEARANCE CENTRIFUGAL PUMP 5 HP HEAD YIN. f` <br /> lU.L. LISTEOI 3'SEN.IP GALV. <br /> .� <br /> STEEL PIPE <br /> PUMP STARTER PRESSURE CONTROL VALVE 12'ABOVE GRADE <br /> ELL CROSS TEE <br /> PIPE(TYP.) <br /> PRESSURE GAUGE FITTING(DUCTILE IRDNI <br /> FLAY SWITCH - AND HOSE BIB - <br /> GALV. STEEL DISCHARGE GROUT 24' <br /> DISCHARGE fSCH. 40 GALV.) DEEP NO. 5 REBAR BENT <br /> ISOLATION VALVE 4'GALV.WELL AROUND FITTING ITYP.) <br /> J'DISCHARGE IRRIGATION 45 SELL 45 SELL% CONCRETE THRUST <br /> MAIN 3'SUCTION LINE 3'SCH. 40 STEEL SUCTION LINE FROM PUMP TO THE 4'WELL(SEE PUMP STATION DETAIL _ BLOCK IMIN.2 CU bt.) <br /> CHECK VALVE 6 WELL GALVANIZED 3'CHECK VALVET im, <br /> UNDISTURBED SOTYP. <br /> ILELECTRIC PAYER SUPPLY VALVE BOXES WITR LOCATE WELL A MAXIMUM D15TANCE OF 20 FT. FROM FINAL PUMP STATION LOCATION SUPPLY LINES J-INCHES IN <br />DIAMETER AND <br /> f5£E PLAN EOR LDCATIONI TOP OF WELL TEE OR LARGER SHALL RECEIVE CONCRETE THRUST BLOCKS. <br /> 510 FITTING 12'BELOW 4'WELL ESTIMATED AT 100 FT. TOTAL DEPTH WITH 20 FT. STAINLESS STEEL SCREEN J'-2 CU.FT. <br /> PUMP PERFORMANCE FINISHED GRADE 4'-2 CU.FT. <br /> 60 GPM o 135 TDH ALL PIPING SHALL BE SCH. 40 GALV. STEEL PIPE 2.INSTALL A PROTECTIVE BARRIER BETWEEN MAUST <br /> WrE BLOCK AND PLT PIPE OR FITTINGS <br /> PUMP STATION DETAIL J WELL/SUCTION LINE THRUST BLOCKS <br /> 'HOOVER' MODEL NO. HCF-SCS_/_-W,E-16 NOT TO SCALE <br /> MOT TO SCALE NOT TO SCALE <br /> DATEREVISIONS <br /> DESCRIPTIONA DESCRIPTION Lw4a�pA"lh.tlae.mia Km.nacaw,IUA nam STATS AP PLQR/LL1 SHEET <br /> Cotleur Hearing BNPARTmEmr oP TR.IMSA'LPTATION No. <br /> IOU CanmouL b Sub ROAD A0. COUNTY FINANCIAL PROJCID <br /> iwka,FluNa]S/SN ET IRRIGATION DETAILS <br /> Sk�T No..LCC T."" SR 5 INDIAN RIVER 228583-3-52-0I LD-15 <br /> - envxp) 9:LOr AY w.000zm.,a ur.rorolFi,-rmnzzesu-a-,rs-wewo-rwwwvvmo-m.q. <br />