My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-044
CBCC
>
Official Documents
>
2010's
>
2010
>
2010-044
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2016 8:04:00 PM
Creation date
10/5/2015 9:01:51 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Grant
Approved Date
02/09/2010
Control Number
2010-044
Agenda Item Number
12.A.1.
Entity Name
Indian River County 2010 EECBG Energy Efficiency Project
Subject
FPL Energy Audit
Supplemental fields
SmeadsoftID
8607
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIAN RIVER COUNTY PHASE 2 <br /> TECHNICAL ENERGY AUDIT <br /> RECOMMENDED ENERGY CONSERVATION MEASURES <br /> FPLES recommends that Indian River County moves forward to implement the occupancy sensors, <br /> as the ECM has the following savings and cost characteristics: <br /> R m <br /> N A IJbz 12,721 7.5 Yrs <br /> (Note: The detailed analyses and cut sheets for this ECM can be found in Appendix N& I) <br /> ECM - 3: Water Conservation <br /> FPLES performed a walkdown of the facility's domestic water system with respect to <br /> installing low flow and. ultra low flow fixtures. As a result, it was determined that savings <br /> can be achieved through the replacement and/or retrofit of water fixtures. The analysis included <br /> determining the consumption of the existing (pre) fixtures, comparing it to the baseline water bill (see <br /> Modeling Methods, Section 3) and determining the consumption of the retrofit (post) fixtures. Once <br /> the post and pre consumption were determined, the savings were calculated based on the current <br /> water/sewer rates. <br /> The identified high water consumption faucets, water closets, and urinals should be replaced at this <br /> facility. The field investigation identified 10 restroom fixtures at the facility. After completion of the <br /> analysis, 9 replacement fixtures were proposed in the water conservation project shown below: <br /> Proposed Water Conservation Fixtures <br /> 111 1111111 NNIIIIIIIS <br /> 4"Sin le Metered Faucet Single Temp 0.5 GPM 3 <br /> Floor Mount Dual Flush Water Closet-Tank 1.6/0.8 1.0 GPF 3 <br /> Floor Mount Dual Flush Water Closet ADA-Tank 1-6/0.8 1.0 GPF 2 <br /> Wall Hung Top Sud Urinal—FV 0.125 GPF 1 <br /> Exclusions contain the following: <br /> • Existing low consumption faucets. <br /> Water conservation hasan annual savings of $503, with a cost of$12,898, and a payback of greater <br /> than 25 Yrs. Therefore, FPLES does not recommends that Indian River County moves forward to <br /> implement the water conservation retrofit. The detailed analyses and cut sheets for this <br /> ECM can be found in Appendix ' & K. <br />
The URL can be used to link to this page
Your browser does not support the video tag.