Laserfiche WebLink
INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />SECTION 102239 - FOLDING GLASS -PANEL PARTITIONS <br />PART 1 - GENERAL <br />1.1 RELATED DOCUMENTS <br />A. Drawings and general provisions of the Contract, including General and Supplementary <br />Conditions and Division 01 Specification Sections, apply to this Section. <br />1.2 SUMMARY <br />A. Section includes manually operated, glass -panel partitions. <br />B. Related Requirements: <br />1. Section 055000 "Metal Fabrications" for supports that attach supporting tracks to <br />overhead structural system. <br />1.3 DEFINITIONS <br />A. STC: Sound Transmission Class. <br />1.4 PREINSTALLATION MEETINGS <br />A. Preinstallation Conference: Conduct conference at Project site . <br />1.5 ACTION SUBMITTALS <br />A. Product Data: For each type of product. <br />B. Shop Drawings: For operable glass -panel partitions. <br />1. Include plans, elevations, sections, details, numbered panel installation sequence, and <br />attachments to other work. <br />2. Indicate stacking and operating clearances. Indicate location and installation requirements <br />for hardware and track, blocking, and direction of travel. <br />C. Samples for Initial Selection: For each type of exposed material, finish, covering, or facing. <br />1. Include Samples of accessories involving color selection. <br />D. Samples for Verification: For each type of exposed material, finish, covering, or facing, <br />prepared on Samples of size indicated below: <br />I. Panel Edge Material: Not less than 3 inches (75 nun) long. <br />FOLDING GLASS -PANEL PARTITIONS 102239.13 - 1 <br />