My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-200C
CBCC
>
Official Documents
>
2010's
>
2014
>
2014-200C
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2018 12:10:05 PM
Creation date
10/5/2015 1:22:27 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
12/09/2014
Control Number
2014-200C
Agenda Item Number
12.F.1 (1 of 2 docs)
Entity Name
Kast Construction Company, LLC
Subject
Contract and Document Specifications
Intergenerational Recreation Facility
Area
South County Regional Park
Supplemental fields
SmeadsoftID
14252
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
400
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />3.3 LABELING AND IDENTIFYING <br />A. Equipment Nameplates and Signs: Install engraved plastic -laminate equipment nameplate or <br />sign on or near each of the following: <br />1. Reduced -pressure -principle backflow preventers. <br />2. Double-check, backflow -prevention assemblies. <br />3. Double-check, detector -assembly backflow preventers. <br />4. Water pressure -reducing valves. <br />5. Calibrated balancing valves. <br />6. Primary, thermostatic, water mixing valves. <br />B. Distinguish among multiple units, inform operator of operational requirements, indicate safety <br />and emergency precautions, and warn of hazards and improper operations, in addition to <br />identifying unit. Nameplates and signs are specified in Section 220553 "Identification for <br />Plumbing Piping and Equipment." <br />3.4 FIELD QUALITY CONTROL <br />A. Perform the following tests and inspections: <br />1. Test each pressure vacuum breaker reduced -pressure -principle backflow preventer and <br />double-check, detector -assembly backflow preventer according to authorities having <br />jurisdiction and the device's reference standard. <br />B. Domestic water piping specialties will be considered defective if they do not pass tests and <br />inspections. <br />C. Prepare test and inspection reports. <br />3.5 ADJUSTING <br />A. Set field -adjustable pressure set points of water pressure -reducing valves. <br />B. Set field -adjustable flow set points of balancing valves. <br />C. Set field -adjustable temperature set points of temperature -actuated, water mixing valves. <br />END OF SECTION 221119 <br />DOMESTIC WATER PIPING SPECIALTIES 221119 - 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.