Laserfiche WebLink
INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />1.6 QUALITY ASSURANCE <br />A. Drainage piping specialties shall bear label, stamp, or other markings of specified testing <br />agency. <br />B. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, <br />Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for <br />intended use. <br />C. Comply with NSF 14, "Plastics Piping Components and Related Materials," for plastic sanitary <br />piping specialty components. <br />1.7 COORDINATION <br />A. Coordinate size and location of concrete bases. Cast anchor -bolt inserts into bases. Concrete, <br />reinforcement, and formwork requirements are specified in Section 033000 "Cast -in -Place <br />Concrete." <br />B. Coordinate size and location of roof penetrations. <br />PART 2 - PRODUCTS <br />2.1 CLEANOUTS <br />A. Metal Cleanouts: <br />1. ASME A112.36.2M, Cast -Iron Cleanouts: <br />a. Manufacturers: Subject to compliance with requirements, provide products by one <br />of the following: <br />1) MIFAB, Inc. <br />2) Smith, Jay R. Mfg. Co. <br />3) Watts Drainage Products. <br />4) Zurn Plumbing Products Group. <br />2.2 FLOOR DRAINS <br />A. Cast -Iron Floor Drains : <br />1. Manufacturers: Subject to compliance with requirements, provide products by one of the <br />following: <br />a. MIFAB, Inc. <br />b. Watts Drainage Products. <br />c. Zurn Plumbing Products Group; Light Commercial Operation. <br />2.3 MISCELLANEOUS SANITARY DRAINAGE PIPING SPECIALTIES <br />A. Deep -Seal Traps: <br />SANITARY WASTE PIPING SPECIALTIES 221319 - 2 <br />