INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS <br />A. In other Part 2 articles where titles below introduce lists, the following requirements apply to <br />product selection: <br />1. Manufacturers: Subject to compliance with requirements, provide products by one of the <br />manufacturers specified. <br />2.2 PIPING MATERIALS <br />A. Refer to Part 3 "Piping Applications" Article for applications of pipe, tube, fitting, and joining <br />materials. <br />2.3 PVC PIPE AND FITTINGS <br />A. Solid -Wall PVC Pipe: ASTM D 2665, drain, waste, and vent. <br />B. Solvent Cement and Adhesive Primer: <br />1. Use PVC solvent cement that has a VOC content of 510 g/L or less when calculated <br />according to 40 CFR 59, Subpart D (EPA Method 24). <br />2. Use adhesive primer that has a VOC content of 550 g/L or less when calculated <br />according to 40 CFR 59, Subpart D (EPA Method 24). <br />PART 3 - EXECUTION <br />3.1 EXCAVATION <br />A. Refer to Division 31 Section "Earth Moving" for excavating, trenching, and backfilling. <br />3.2 PIPING APPLICATIONS <br />A. Aboveground storm drainage piping shall be one of the following: <br />Solid -wall PVC pipe, PVC socket fittings, and solvent -cemented joints. <br />B. Underground storm drainagepiping shall be one of the following: <br />1. Solid -wall PVC pipe, PVC socket fittings, and solvent -cemented joints. <br />3.3 PIPING INSTALLATION <br />A. Storm sewer and drainage piping outside the building are specified in Civil Specifications <br />"Storm Utility Drainage Piping." <br />STORM DRAINAGE PIPING 221413 - 2 <br />