My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-200C
CBCC
>
Official Documents
>
2010's
>
2014
>
2014-200C
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2018 12:10:05 PM
Creation date
10/5/2015 1:22:27 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
12/09/2014
Control Number
2014-200C
Agenda Item Number
12.F.1 (1 of 2 docs)
Entity Name
Kast Construction Company, LLC
Subject
Contract and Document Specifications
Intergenerational Recreation Facility
Area
South County Regional Park
Supplemental fields
SmeadsoftID
14252
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
400
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />4. Serial communication capabilities shall include, but not be limited to; run -stop control, <br />speed set adjustment, proportional/integral/derivative PID control adjustments, current <br />limit, accel/decel time adjustments, and lock and unlock the keypad. The drive shall have <br />the capability of allowing the DDC to monitor feedback such as process variable <br />feedback, output speed / frequency, current (in amps), % torque, power (kW), kilowatt <br />hours (resettable), operating hours (resettable), and drive temperature. The DDC shall <br />also be capable of monitoring the VFD relay output status, digital input status, and all <br />analog input and analog output values. All diagnostic warning and fault information shall <br />be transmitted over the serial communications bus. Remote VFD fault reset shall be <br />possible. <br />5. Serial communication in bypass shall include, but not be limited to; bypass run -stop <br />control, the ability to force the unit to bypass, and the ability to lock and unlock the <br />keypad. The bypass shall have the capability of allowing the DDC to monitor feedback <br />such as, current (in amps), kilowatt hours (resettable), operating hours (resettable), and <br />bypass logic board temperature. The DDC shall also be capable of monitoring the <br />bypass relay output status, and all digital input status. All bypass diagnostic warning and <br />fault information shall be transmitted over the serial communications bus. Remote <br />bypass fault reset shall be possible. <br />6. The VFD / bypass shall allow the DDC to control the drive and bypass digital and analog <br />outputs via the serial interface. This control shall be independent of any VFD function. <br />The analog outputs may be used for modulating chilled water valves or cooling tower <br />bypass valves. The drive and bypass' digital (Form -C relay) outputs may be used to <br />actuate a damper, open a valve or control any other device that requires a maintained <br />contact for operation. In addition, all of the drive and bypass' digital inputs shall be <br />capable of being monitored by the DDC system. This allows for remote monitoring of <br />which (of up to 4) safeties are open. <br />7. The VFD shall include an independent PID loop for customer use. The independent PID <br />loop would be used for chilled water value control. Both the VFD PID control loop and <br />the independent PID control loop shall continue functioning even if the serial <br />communications connection is lost. As default, the VFD shall keep the last good set point <br />command and last good DO & AO commands in memory in the event the serial <br />communications connection is lost and continue controlling the process. <br />G. EMI / RFI filters. All VFD's shall include EMI/RFI filters. The onboard filters shall allow the VFD <br />assembly to be CE Marked and the VFD shall meet product standard EN 61800-3 for the First <br />Environment restricted level with up to 100 feet of motor cable. No Exceptions. Certified test <br />reports shall be provided with the submittals confirming compliance to EN 61800-3, First <br />Environment. <br />H. All VFD's through 25HP at 480 V shall be protected from input and output power mis-wiring. <br />The VFD shall sense this condition and display an alarm on the keypad. The VFD shall not <br />sustain damage from this power mis-wiring condition. <br />ADDITIONAL FEATURES — Optional features to be furnished and mounted by the drive <br />manufacturer. All optional features shall be UL Listed by the drive manufacturer as a complete <br />assembly and carry a UL508 label. <br />1. Fieldbus adapters - BACnet IP, shall be provided by adding of an optional card. <br />J. BYPASS CONTROLLER <br />1. A complete factory wired and tested bypass system consisting of a door interlocked, <br />padlockable circuit breaker, output contactor, bypass contactor, and fast acting VFD input <br />fuses are required. UL Listed motor overload protection shall be provided in both drive <br />and bypass modes. <br />VARIABLE FREQUENCY MOTOR CONTROLLERS 230514 - 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.