Laserfiche WebLink
INDIAN RIVER COUNTY JULY 25, 2014 <br />INTERGENERATIONAL RECREATION CENTER 100% CONSTRUCTION DOCUMENTS <br />B. Proceed with installation only after unsatisfactory conditions have been corrected. <br />3.2 INSTALLATION <br />A. Install sound -absorbing wall units in locations indicated with vertical surfaces and edges plumb, <br />top edges level and in alignment with other units, faces flush, and scribed to fit adjoining work <br />accurately at borders and at penetrations. <br />B. Comply with sound -absorbing wall unit manufacturer's written instructions for installation of <br />units using type of mounting devices indicated. Mount units securely to supporting substrate. <br />C. Align and level fabric pattern and grain among adjacent units. <br />3.3 INSTALLATION TOLERANCES <br />A. Variation from Plumb and Level: Plus or minus [1/16 inch (1.6 mm)]. <br />B. Variation of Panel Joints from Hairline: Not more than [1/16 inch (1.6 mm)] [1/32 inch (0.79 <br />mmwide. <br />3.4 CLEANING <br />A. Clip loose threads; remove pills and extraneous materials. <br />B. Clean panels on completion of installation to remove dust and other foreign materials according <br />to manufacturer's written instructions. <br />END OF SECTION 098433 <br />SOUND -ABSORBING WALL UNITS 098433 - 5 <br />