My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-221A
CBCC
>
Official Documents
>
2010's
>
2015
>
2015-221A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2018 12:56:59 PM
Creation date
12/9/2015 11:53:13 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
11/17/2015
Control Number
2015-221A
Agenda Item Number
8.G.
Entity Name
Ranger Construction
Subject
Resurface CR 512 from 125th Ave. to I-95
Contracts and Specifications
Area
125th Ave.to I-95
Project Number
1304
Bid Number
2016003
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
227
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(1) Vertical Feature Accuracy: <br />(a) Vertical Control: Field -measured control for elevation information shown <br />upon survey maps or reports shall be based on a level loop or closure to a <br />second benchmark. <br />❑ (b) Closure in feet must be accurate to a standard of plus or minus .05 ft. <br />times the square root of the distance in miles. <br />❑ (c) All surveys and maps or reports with elevation data shall indicate the <br />datum and a description of the benchmark(s) upon which the survey is based. <br />❑ (d) Minor elevation data may be obtained on an assumed datum provided the <br />base elevation of the datum is obviously different than the established datum. <br />(2) Horizontal Feature Accuracy: <br />❑ (a) Horizontal Control: All surveys and maps or reports expressing or <br />displaying features in a publicly published coordinate system shall indicate <br />the coordinate datum and a description of the control points upon which the <br />survey is based. <br />❑ (b) Minor coordinate data may be obtained and used on an assumed datum <br />provided the numerical basis of the datum is obviously different than a <br />publicly published datum. <br />❑ (c) The accuracy of control survey data shallbe verified by redundant <br />measurements or traverse closures. All control measurements shall achieve <br />the following closures: <br />Commercial/High Risk Linear: 1 foot in 10,000 feet; <br />Suburban: Linear: 1 foot in 7,500 feet; <br />Rural: Linear: 1 foot in 5,000 feet; <br />❑ (d) When statistical procedures are used to calculate survey accuracies, the <br />maximum acceptable positional tolerance, based on the 95% confidence <br />level, should meet the same equivalent relative distance standards as set <br />forth in 61G17- 6.003(3)(p)(2.)(c) F.A.C. <br />❑ (e) Intended Display Scale: All maps or reports of surveys produced and <br />delivered with digital coordinate files must contain a statement to the effect <br />of: "This map is intended to be displayed at a scale of 1/_ or smaller". <br />61G17-6.004 Specific Survey, Map, and Report Requirements <br />(1) As-Built/Record Survey: <br />❑ (a) Obtained field measurements of vertical or horizontal dimensions of <br />constructed improvements so that the constructed facility can be delineated <br />in such a way that the location of the construction may be compared with the <br />construction plans. <br />01025-9 Technical Specifications <br />F:\Public Works\ENGINEERING DIVISION PROJECTS \1304 -CR 512 Resurf (SCOP)_125th Ave to I-951Admim\bid documents\Master <br />Contract Documents\Technical Specifications.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.