My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-000 (2)
CBCC
>
Official Documents
>
2010's
>
2013
>
2013-000 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2018 12:54:31 PM
Creation date
3/23/2016 9:12:18 AM
Metadata
Fields
Template:
Official Documents
Official Document Type
Bid
Approved Date
08/20/2013
Control Number
2013-000
Subject
Fertilizer and Landscape Management
Area
Old Dixie Highway Sidewalk 38th Lane to 45th Street
Alternate Name
Sidewalk Improvements
Supplemental fields
FilePath
H:\Indian River\Network Files\SL00000I\S0005EA.tif
Meeting Body
Board of County Commissioners
Meeting Type
BCC Regular Meeting
SmeadsoftID
14586
Document Relationships
2013-014
(Agenda)
Path:
\Ordinances\2010's\2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
178
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
on all such disturbed areas within 7 days after the construction activity in that portion of <br /> the site has temporarily or permanently ceased, unless final landscaping has been <br /> installed. Polyacrylamide application shall be as specified herein. <br /> D. Inspect each pollution control system at least once per day and after each rainfall <br /> event. Clean and maintain each pollution control system as required by its <br /> manufacturer or the OWNER, until the system is no longer needed. If a water quality <br /> violation occurs, immediately cease all work contributing to the water quality violation <br /> and correct the problem. <br /> E. Discharge shall not violate State or local water quality standards in the receiving <br /> waters, nor cause injury to the public health or to public or private property, nor to the <br /> Work completed or in progress. The receiving point for water from construction <br /> operations shall be approved by the applicable owner, regulatory agency, and the <br /> ENGINEER. <br /> F. Promptly repair all damage at no cost to the OWNER. <br /> 1.4 SUBMITTALS <br /> A. Shop Drawings: Submit shop drawings of the proposed pollution control and treatment <br /> systems in accordance with Section 1340. <br /> B. Stormwater Pollution Prevention Plan. <br /> 1.5 STATE CERTIFIED EROSION CONTROL SPECIALTY SUBCONTRACTOR IS <br /> REQUIRED FOR INSTALLATION, AND MAINTENANCE <br /> A. State Certified Erosion Control Specialty Subcontractor is Required for Installation and <br /> Maintenance: Installation and maintenance of all erosion and stormwater pollution <br /> control devices, shall be by a State Certified erosion control subcontractor who <br /> specializes in the installation and maintenance of such devices. After installation, this <br /> specialty subcontractor shall maintain the erosion and stormwater pollution control <br /> devices until in the ENGINEER's sole opinion, the devices are no longer necessary <br /> (such time not to extend past the date the OWNER formally accepts the project as <br /> complete). Before beginning construction, submit to Indian River County for review <br /> and approval, a Stormwater Pollution Prevention Plan (SWPPP), prepared by the <br /> certified erosion control subcontractor. Construction shall not begin until the SWPPP <br /> has been approved by Indian River County. Submit the approved SWPPP to the <br /> ENGINEER before beginning construction. Include in the SWPPP, the "Contractor's <br /> Affidavit Regarding Erosion Control and Treatment of Dewatering Water and <br /> Stormwater From the Construction Site" (located at the end of this Section). <br /> 1.6 "POLLUTION"AND CERTAIN UNCONTESTABLE POLLUTION EVENTS DEFINED <br /> A. With respect to this Section and as may be further defined in paragraphs 1.6.13, 1.6.C, <br /> 01025-15 Technical Specifications <br /> FAPublic Works\ENGINEERING DIVISION PROJECTS\084513-Old Dixie Hwy Sidewalk(38th Ln-45th St)\Admim\bid <br /> documents\Master Contract Documents\Technical Specifications.doc <br />:.jq <br />
The URL can be used to link to this page
Your browser does not support the video tag.