Laserfiche WebLink
SILENCER ANNUNCIATING LIGHT <br /> RESET NAME PLATE (TYPICAL) <br /> CONTROL PANEL <br /> (SEE NOTE 12) 2'0 PRE—PUNCHED <br /> 4 <br /> ELECTRICAL <br /> CONNECTION HOLE <br /> MOTOR CABLE (TYP) 0 0 0 <br /> CONDUIT SEAL BUSHING TM E T RED COLOR FLASHING ALARM <br /> (WATERTIGHT TO PREVENT LIGHT WITH CAGE <br /> MOISTURE AND GAS FROM <br /> ENTERING CONTROL PANEL BOX) <br /> MATCH CABLE (FURNISHED <br /> WITH PUMP) 0 0 o RUN INDICATING LIGHTS <br /> HOA <br /> EMERGENCY GENERATOR I <br /> RECEPTACLE SEE TERMINAL BLOCK FOR <br /> SPECIFICATIONS FOR EXTERNAL ALARMS <br /> RECEPTACLE MODEL <br /> # <br /> #14 TO RTU (FROM VALVE PIT) <br /> ALARM HORN #1 #3 #4 2' ALUMINUM CONDUIT TO STATION (MIN) <br /> CONFIRM WITH PUMP MANUFACTURER <br /> REFER TO SECTION 10 FRONT VIEW <br /> SUBMERSIBLE WASTEWATER TYPICAL CONTROL PANEL <br /> PUMPING STATI❑N <br /> CONTROL PANEL <br /> (SEE NOTE 12) <br /> (2) 4' ALUMINUM <br /> SCH 40 NOTES POSTS (TYP) <br /> 1. ELECTRIC SERVICE SHALL BE 3 _ SERVICE DISCONNECT <br /> METER !— (STAINLESS STEEL) <br /> PHASE. ENCASED <br /> 2. ALARM HORN SHALL BE SEALED TO PLAN VIEW <br /> PREVENT LEAKAGE. <br /> 3. CONTROL PANEL TO BE APPROVED VARIES <br /> BY IRCDUS BEFORE INSTALLATION. METE I CONTROL PANEL <br /> 4. REFER TO SECTION 8 FOR PUMPING ALUMINUM UNISTRUT <br /> STATION SPECIFICATIONS. BRACING \2 REWD. <br /> 5. BOTTOM OF PANEL TO BE 28' TO 0 SERVICE <br /> 34' ABOVE GROUND. DISCONNECT <br /> 6. DISCONNECT BETWEEN METER ANDZ SCH 4' AL40 UMINUM <br /> PPORT <br /> PANEL TO BE STAINLESS STEEL i POSTS (TYP) <br /> NON FUSABLE. <br /> 7, ALL HARDWARE AND FASTENERS # 3/0 BARE COPPER WIRE <br /> TO BE STAINLESS STEEL. GROUND CLAMP <br /> 8. TOOLS & SPARE PARTS (SEE SECTION 10.05) HOSE BIBB+� <br /> 9. CONTROL PANEL SHALL MEET THE SEE NOTE 13 FINISH GRADE <br /> REQUIREMENTS OF SERVICE ENTRANCE <br /> BY PROPERLY BONDING OR SHALL BE _ <br /> UL SERVICE ENTRANCE RATED. [\� <br /> 3000PS POURED AGAINSTA10. CDNTRDL PANEL SHALL HAVE A DATA 2' MIN \ \\// UNDISTURBED SOIL <br /> FLOW, FLOAT BY—PASS SWITCH. \ 0' LOW <br /> THE MAXIMUM HORSEPOWER RATING FOR \\ \� \''� �\ c%PERVELDIGROUr01 ROD <br /> A 240 VOLT LIFT STATION SERVICE IS 20 H.P. i/ <br /> ANY PUMP SIZE GREATER THAN 20 H.P. NEEDS 12' MIN 2' PVC TUBE <br /> A 480 VOLT SERVICE. <br /> 12. THE CONTROL PANEL SHALL BE 4X NEMA, CONDUIT TO POWER CONDUITS TO PUMPING <br /> WHITE POWDER COATED STAINLESS STEEL. POLE SEE SITE PLAN STATION (SEE PLAN) <br /> 13. WATER SERVICE LINE (1'0) WITH REDUCED PRESSURE FRONT ELEVATION <br /> BACKFLOW PREVENTER, WATER METER AND <br /> HOSE BIBB REQUIREDUIRED.. TYPICAL SERVICE ENTRANCE STRUCTURE <br /> 4tSVEl� DRAWING <br /> INDIAN RIVER COUNTY �� TYPICAL PUMPING STATI❑N NO. <br /> DEPARTMENT of (ELECTRICAL DETAILS) <br /> UTILITIES SERVICES S - 18 <br /> �LORI�� MARCH 2m4 <br /> .3 .X4. 3q. <br />