Laserfiche WebLink
These values are reasonably similar. The field data will be used in the following analysis regarding design loads and <br /> projected reductions.To complete this review,the flows and water quality associated with the RO Concentrate,which is to be <br /> blended at an average ratio of 10:1 with flows from the South Relief Canal, needs to be included. The RO Concentrate is a <br /> highly mineralized, low suspended solids flow with a near neutral pH, and water temperatures consistently at about 26° C. <br /> The flow rate is presently about 1 MGD. Based upon data collected during the ongoing pilot investigation,the design water <br /> quality for the RO Concentrate is as noted in Table 4. <br /> Table 4: Desist►Concentrations Ro Concentrate,South Relief Canal and 10:1 Blend <br /> Units RO Concentrate Canal Value 10:1 Design <br /> Value Average Blend Annual <br /> Average Value <br /> Average <br /> Total P m L 0.033 0.240 0.221 <br /> Total N m L 1.57 1.05 1.10 <br /> Ammonia-N m /L 0.94 0.09 0.17 <br /> TSS m L <2 11 10 <br /> Alkalinity g/L a 723 178 228 <br /> Conductive micros/cm 6,135 1,941 2,322 <br /> Color pcu 11 39 36 <br /> * Value is typically directly related to concentration in feed water <br /> **Typically directly related to water temperature <br /> Accordingly, based upon flows of 10 MGD from the canal and I MGD as RO Concentrate, the annual design loads to the <br /> Algal Turf Scrubber®(ATSTM)treatment unit shall be as noted in Table 5. To determine the reduction associated with these <br /> loads through the Algal Turf Scrubber®, a first order model —ATSDEM—which is based upon the Monod relationship. <br /> ATSDEM was developed by HydroMentia, Inc. of Ocala, Florida6, and will be applied to the water quality and flow <br /> conditions. The model is based upon projections of specific growth rates and community productivity for the Algal Turf <br /> Community, which has been shown to be a function of total phosphorus levels; hydraulic loading rate;temperature; tissue <br /> nutrient levels and average standing crop.Critical input parameters are noted in Table 6. <br /> Table 5: Design Pollutant Loads from 11 MGD Design Flow Blend <br /> Units 10:1 Design <br /> Design Pollutant Loads Blend Annual <br /> Value <br /> Total P lb/year 7,400 <br /> Total N lb/year 36,834 <br /> TSS lb/year 334,851 <br /> Table 6:Critical Input Parameters ATSDEM <br /> 6 This model was developed as part of the Contact C-13933 between HydroMentia, Inc and the South Florida Water <br /> Management District. "S-154 Pilot Single Stage Algal Turf Scrubber® Final Report" Submitted to the South Florida Water <br /> Management District.March 2005. <br /> DEP Agreement No.G0353,Attachment A-1,Page 11 of 14 <br /> 143 <br />