Laserfiche WebLink
WR#4570239 <br /> 7. Before FPL can begin its engineering work on the underground electric distribution facilities,the Customer shall provide FPL with the following: <br /> a) Paving,grading,and drainage plans showing all surface and sub-surface drainage satisfactory to FPL, <br /> b) A construction schedule, <br /> c) An estimate of when electric service will be required,and <br /> d) Copies of the Customer's final construction plans as well as other construction drawings(plot,site,sewage,electrical,etc.)requested by FPL <br /> plats provided by the Customer must be either recorded by the circuit clerk or other recording officer or prepared and certified as meeting the <br /> requirements for recording(except approval by the governing body)by a registered land surveyor. <br /> 8. Prior to FPL construction pursuant to this agreement,the Customer shall: <br /> a) Clear the FPL easement on the Customer's property of tree stumps,all trees,and other obstructions that conflict with construction,including <br /> the drainage of all flooded areas. The Customer shall be responsible for clearing, compacting, boulder and large rock removal, stump <br /> removal,paving and addressing other special conditions. The easement shall be graded to within six inches of final grade with soil stabilized. <br /> b) Provide property line and corner stakes, designated by a licensed surveyor, to establish a reference for locating the underground cable <br /> trench route in the easement and additional reference points when required by FPL. Also,the Customer shall provide stakes identifying the <br /> location,depth,size and type facility of all non-FPL underground facilities within or near the easement where FPL distribution facilities will be <br /> installed. The Customer shall maintain these stakes,and if any of these stakes are lost,destroyed or moved and FPL requires their use,the <br /> Customer shall replace the stakes at no cost to FPL, unless the stakes are lost,destroyed or moved by an agent,employee, contractor or <br /> subcontractor of FPL,in which case FPL will pay the Customer the cost of replacing the stakes. <br /> c) It is further understood and agreed that subsequent relocation or repair of the FPL system,once installed,will be paid by the Customer if said <br /> relocation or repair is a result of a change in the grading by the Customer or any of the Customer's contractors or subcontractors from the <br /> time the underground facilities were installed;and,that subsequent repair to FPL's system,once installed,will be paid by the Customer if said <br /> repair is a result of damage caused by the Customer or any of the Customer's contractors or subcontractors. <br /> d) Provide sufficient and timely advance notice 45 days)as required by FPL,for FPL to install its underground distribution facilities prior to the <br /> installation of paving, landscaping, sodding, sprinkler systems, or other surface obstructions. In the absence of sufficient coordination, as <br /> determined by FPL,by the Customer,all additional costs for trenching and backfilling shall be paid by the Customer,and none of the costs of <br /> restoring paving, landscaping, grass, sprinkler systems and all other surface obstructions to their original condition,should they be installed <br /> prior to FPL's facilities,shall be borne by FPL. <br /> e) Pay for all additional costs incurred by FPL which may include, but are not limited to, engineering design, administration and relocation <br /> expenses,due to changes made subsequent to this agreement on the subdivision or development layout or grade. <br /> Provide applicable trenching,backfilling,installation of Company provided conduit and other work in accordance with FPL specifications more <br /> 0 PP� 9. 9.� p YP P <br /> particularly described on Exhibit B attached hereto. At the discretion of FPL, either correct any discrepancies, within two(2)working days, <br /> found in the installation that are inconsistent with the instructions and specifications attached to this agreement or pay the associated cost to <br /> correct the installation within thirty(30)days of receiving the associated bill, and in either case, reimburse FPL for costs associated with lost <br /> crew time due to such discrepancies. <br /> g) Provide a meter enclosure, downpipe and ell which meet all applicable codes and FPL specifications and which will accommodate FPL's <br /> service cable size and design. These items must be confirmed with FPL prior to purchase. FPL will not be responsible for costs involved in <br /> modifying or replacing items which do not meet the above criteria. <br /> 9. FPL shall: <br /> a) Provide the Customer with a plan showing the location of all FPL underground facilities, point of delivery, and transformer locations and <br /> specifications required by FPL and to be adhered to by the Customer. <br /> b) Install,own,and maintain the electric distribution facilities up to the designated point of delivery except when otherwise noted. <br /> c) Request the Customer to participate in a pre-construction conference with the Customer's contractors,the FPL representatives and other utilities <br /> within six(6)weeks of the start of construction. At the pre-construction conference, FPL shall provide the Customer with an estimate of the date <br /> when service may be provided. <br /> 10. This Agreement is subject to FPL's Electric Tariff,including but not limited to the General Rules and Regulations for Electric Service and the Rules of <br /> the Florida Public Service Commission,as they are now written,or as they may be revised,amended or supplemented. <br /> 11.This agreement shall inure to the benefit of,and be binding upon,the successors and assigns of the Customer and FPL. <br /> The Customer and FPL will coordinate closely in fulfilling obligations in order to avoid delays in providing permanent electric service at the time of the <br /> Customer's receipt of a certificate of occupancy. <br /> A ed: <br /> Accepted: <br /> or FPL(Date) <br /> _ Customer (Date) <br /> Witness (Date) <br /> r <br /> Witness (Date) <br /> 35 <br />