My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
04/23/2013AP
CBCC
>
Meetings
>
2010's
>
2013
>
04/23/2013AP
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/26/2018 1:27:47 PM
Creation date
3/23/2016 8:57:14 AM
Metadata
Fields
Template:
Meetings
Meeting Type
BCC Regular Meeting
Document Type
Agenda Packet
Meeting Date
04/23/2013
Meeting Body
Board of County Commissioners
Book and Page
158
Supplemental fields
FilePath
H:\Indian River\Network Files\SL00000E\S0004N6.tif
SmeadsoftID
14211
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-- Complete Alarm, Inc. <br /> 637 Sebastian Blvd. <br /> Sebastian, FI. 32958 <br /> Indian River: (772) 388-0533 Brevard: (321)726-0601 St. Lucie: (772) 344-3444 <br /> Fax: (772) 388-2411 <br /> www.completeelectricinc.com <br /> Date: Jan 21 2013 <br /> Name: Proctor Construction <br /> Addr ess: <br /> City: <br /> Phone: <br /> Fax: <br /> Re: IRC CSI FIRE <br /> Complete Alarrn, Inc. Is Pleased To Present You, With The Quote Detailed Below: <br /> The panel that exists in the current building is a four zone conventional panel. <br /> The zones are used up. <br /> Zone 1 pull station <br /> Zone 2 smoke detector <br /> Zone 3 water flow <br /> Zone 4 tamper switch. <br /> The current panel is not programmable to configure and monitor the pre-action system. <br /> Even if I put all smoke detectors on one zone the panel cannot decipher which room <br /> smoke detector has activated <br /> And the remote Ann. would just beep and illuminate zone 2 smoke detectors. Which <br /> room will they check first? <br /> If a pull station were to be pulled it would also release the pre action or allow water flow <br /> into the dry pipe. <br /> Suggestions, install a new small addressable fire panel as existing will not handle the <br /> additional zones. <br /> This would protect these 7 rooms and alert which room set off its smoke detector at the <br /> remote ann. Panel. <br /> It would also enable programming of the pre-action system. <br /> Scope of work proposed <br /> Provide and install small addressable fire alarm panel to include, <br /> 1 FACP, 10 Smoke Detectors, 1 Pull Station, 1, remote ann., 2 relays for pre action <br /> system, 1 emergency abort button, 2 phone lines, surge protection, 3 monitor modules, <br /> engineered drawings with stamp,permitting and inspections. <br /> All cabling plenum rated and installed in j-hooks. <br /> 90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.