Official Document Type
Contract
Approved Date
09/16/2014
Control Number
2014-129A
Agenda Item Number
8.E.
Entity Name
Timothy Rose
Subject
Contract and Specifications
Old Dixie Highway Resurfacing
Area
I.R.F.W.C.D. North Relief Canal to 71st. ST.
Project Number
1137
Bid Number
2014044
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION —1000- WATER AND SEWER UTILITIES <br />A. Water Utilities <br />The water utilities for this project shall be constructed per the "Indian River County <br />Department of Utility Services Water & Wastewater Standards", March, 2014. This <br />document can be obtained online at www.ircutilities.com <br />Relocation of existing fire hydrants shall include the cost of all pipe, fittings, retaining <br />rods, trenching grading, and incidental items associated with relocation. <br />B. Sewer Utilities <br />The sewer utilities for this project shall be constructed per the "Indian River County <br />Technical Specifications", March, 2014. This document can be obtained online at <br />www.ircutilities.com <br />C. Earthwork and Backfill <br />Compaction - All fill must be compacted by hand tamping from under the pipe up to the <br />center line. Backfill shall be compacted in 6" lifts up to the surface to achieve a <br />minimum compaction of 98 percent of maximum density in roadways and shoulders <br />and 95 percent in easements, in accordance with AASATO T-180 and D-2167. <br />D. Ductile Iron Pipe and Fittings <br />1. General: <br />All ductile iron pipe shall be manufactured in accordance with AWWA <br />Specifications C-150 & C-151. All buried ductile iron pipe shall be <br />manufactured in accordance with AWWA Specification C-151 and shall <br />be Class 52 minimum. All exposed ductile iron pipe shall be Class 53 <br />minimum. <br />2. Fittings: <br />All underground fittings shall be either bell and spigot, or mechanical <br />joint. Mechanical joints shall conform to AWWA specification C1IO <br />(ANSI 21.10-87), or latest revision. All exposed aboveground fittings <br />shall be flanged joint. <br />3. Bell and Spigot Connections: <br />Joints in bell and spigot pipe shall be push -on, mechanical, or restrained <br />joints in accordance with AWWA Standard C-111 (ANSI 21.11-85), or <br />latest revision. Mechanical joint pipe set -screw type retainer glands will <br />not be permitted. <br />4. Flanged Connections: <br />Flanged pipe with screwed -on flanges shall be furnished with long hubs, <br />and the flanges shall be screwed on the threaded end of the pipe in the <br />shop, and the face of the flange and end of pipe refaced together. There <br />01025-37 Technical Specifications <br />F:\PublicWorks\ENGINEERING DIVISION PROJECTS\1137-0Id Dixie Hwy Resurfacing IRF North Relief Canal to 71st <br />St\Admim\Addendums\Technical Specifications ADDENDUM 1 07-31-2014.doc <br />