Laserfiche WebLink
i <br /> REI ENGINEERS <br /> 24600 S. TAMIAMI TRAIL, SUITE 212-315, BONITA SPRINGS, FL 34134 <br /> Fei <br /> PHONE 800.495.9028 FAx 704.596.0533 ENGINEERS <br /> September 3,2014 <br /> Indian River County <br /> 4305a 43rd Avenue <br /> Vero Beach,FL 32967 <br /> Attention: Christopher D.Burr <br /> Facilities Manager <br /> Reference: Proposal for Engineering Services <br /> Health Department Exterior Envelope Evaluation <br /> REI Proposal No.P14FTM-013 <br /> Dear Mr. Burr: <br /> In response to my recent discussion with Cathy Daniel and your subsequent request, REI Engineers, Inc. <br /> (REI) is pleased to submit this proposal for your consideration. It is our understanding that this <br /> evaluation will include the roof, walls and windows of the Health Department facility at 1900 27th St, <br /> Vero Beach, FL 32960. Based on our review of available satellite imagery, the subject building is a two <br /> story facility with a footprint measuring approximately 20,000 square feet(40,000 sf total floor space). A <br /> summary of the work included in this proposal is as follows: <br /> A. Conduct site visit to interview appropriate facility personnel and review the condition of the <br /> exterior envelope components(roofs,walls,windows)to determine the need for remediation. <br /> 1. All reasonably accessible, exposed exterior surfaces of the facility will be carefully <br /> examined to locate specific problems and evaluate the overall needs of the area(s) in <br /> question. <br /> 2. Roof core samples will be taken on unconfirmed areas to determine conditions and <br /> composition of system in place. In addition to reporting the type of components,typical <br /> comments relate to adhesion, delamination, deterioration, moisture content and <br /> anticipated service life. All openings in the system will be repaired with compatible <br /> materials. Core samples will not be taken where deemed inappropriate due to possible <br /> warranty issues, questionable conditions/materials,etc. <br /> 3. Photographs will be taken as necessary to document our observations <br /> B. Issue a report sealed by a Florida Licensed Professional Engineer outlining the results of our field <br /> evaluation. <br /> 1. The report will include a summary of our findings, photographs, roof plans and <br /> elevations as well as recommendations for immediate(emergency) and long term repairs <br /> with estimated construction costs. <br /> a. If roof replacement is necessary, budget figures will be provided for a variety of <br /> roof system types. <br /> ROOFING,WATERPROOFING AND BUILDING ENVELOPE ENGINEERS AND CONSULTANTS <br /> www.reiengineers.com <br /> AN EMPLOYEE-OWNED COMPANY <br />