My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-056B
CBCC
>
Official Documents
>
2010's
>
2017
>
2017-056B
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/26/2017 10:10:21 AM
Creation date
5/16/2017 12:18:10 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
04/18/2017
Control Number
2017-056B
Agenda Item Number
12.F.1
Entity Name
Timothy Rose Construction
Subject
CR 512 Westbound Resurfacing
CR 512 Eastbound Resurfacing
Area
Roseland Road to US1 Easy St. to US1
Project Number
1139
Bid Number
2017034
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
241
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SURVEY CONTROL <br />1. Install/re-establish: It shall be the contractor's responsibility to hire a <br />Professional Surveyor and Mapper as defined per Chapter 472, Florida <br />Statutes, to replace any horizontal and vertical control shown on the <br />engineering plans that was destroyed during construction. <br />2. New roadway alignment control points (survey baseline or controlling line and all <br />points as indicated on the plans or control sheet) upon final roadway completion. <br />Include all intersections and side streets. State plane coordinates and <br />elevations for all control points. <br />3. If shown on plans or not: Any Public Land Corner or Governmental Survey <br />Control point(s),vertical control (bench marks), property corners destroyed <br />and/or disturbed during the scope of the project shall be properly re-established <br />as per standards as set forth within Florida Statutes, Administrative code and <br />Minimum Technical Standards for that type of survey. All said surveying <br />mentioned above shall be performed under the direct supervision of a <br />registered Professional Surveyor and Mapper in the state of Florida and <br />certified accordingly. Said Governmental agency(s) shall be notified in writing of <br />disturbance and re -establishments. <br />RECORD/AS-BUILTS DRAWINGS FORMAT - SUBMITTAL <br />A. ENGINEER will supply the CONTRACTOR with the electronic file of the <br />approved construction plans for the input of the As -Built (record) information. <br />B. CONTRACTOR shall deliver three (3) certified sets of Record/As-Builts with <br />Electronic Drawing files prepared in AutoCAD Civil 3D 2013 AND PDF format or <br />in current version as agreed by the ENGINEER. <br />C. CONTRACTOR's surveyor shall review, sign and seal As-Builts or Record <br />drawing(s). Said drawing(s) shall clearly state type of survey, positional <br />tolerances, adhere and be certified to by a registered Professional Surveyor and <br />Mapper in the state of Florida, any standards set forth by Florida Statutes, <br />Administrative code and Minimum Technical Standards for As-Built/Record <br />surveys. <br />D. All Record/As-Built drawings are subject to review and approval by County <br />Surveyor. <br />ACCURACY <br />The CONTRACTOR will be held responsible for the accuracy and completeness of <br />Record Drawings and Electronic As-Builts and shall bear any costs incurred in finding <br />utilities as a result of incorrect data furnished by the CONTRACTOR. <br />01025-5 Technical Specifications <br />F•\Public Works\ENGINEERING DIVISION PROJECTS\1139-CR 512 Wbnd Resurfacing -Roseland Rd to US 1-SCOP\Admin\bid <br />documents\Master Contract Documents\Technical Specifications REVISED.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.