My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-086A
CBCC
>
Official Documents
>
2010's
>
2017
>
2017-086A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2017 10:49:06 AM
Creation date
7/12/2017 4:25:16 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Contract
Approved Date
06/13/2017
Control Number
2017-086A
Agenda Item Number
8.C.
Entity Name
Indian River County Courthouse
Subject
Judge's Security Upgrade Project
Area
Courthouse
Project Number
IRC-1621
Bid Number
2017050
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
245
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
connection, float level settings, any deviation from the plans, and serial number(s) of <br />the pump(s). <br />SURVEY CONTROL <br />1. Install/re-establish: It shall be the contractor's responsibility to hire a <br />Professional Surveyor and Mapper as defined per Chapter 472, Florida <br />Statutes, to replace any horizontal and vertical control shown on the <br />engineering plans that was destroyed during construction. <br />2. New roadway alignment control points (survey baseline or controlling line and all <br />points as indicated on the plans or control sheet) upon final roadway completion. <br />Include all intersections and side streets. State plane coordinates and <br />elevations for all control points. <br />3. If shown on plans or not: Any Public Land Corner or Governmental Survey <br />Control point(s),vertical control (bench marks), property corners destroyed <br />and/or disturbed during the scope of the project shall be properly re-established <br />as per standards as set forth within Florida Statutes, Administrative code and <br />Minimum Technical Standards for that type of survey. All said surveying <br />mentioned above shall be performed under the direct supervision of a <br />registered Professional Surveyor and Mapper in the state of Florida and <br />certified accordingly. Said Governmental agency(s) shall be notified in writing of <br />disturbance and re -establishments. <br />RECORD/AS-BUILTS DRAWINGS FORMAT - SUBMITTAL <br />A. ENGINEER will supply the CONTRACTOR with the electronic file of the <br />approved construction plans for the input of the As -Built (record) information. <br />B. CONTRACTOR shall deliver seven (7) certified sets of Record/As-Builts with <br />Electronic Drawing files prepared in AutoCAD Civil 3D 2013 AND PDF format <br />or in current version as agreed by the ENGINEER. <br />C. CONTRACTOR's surveyor shall review, sign and seal As-Builts or Record <br />drawing(s). Said drawing(s) shall clearly state type of survey, positional <br />tolerances, adhere and be certified to by a registered Professional Surveyor <br />and Mapper in the state of Florida, any standards set forth by Florida Statutes, <br />Administrative code and Minimum Technical Standards for As-Built/Record <br />surveys. <br />D. All Record/As-Built drawings are subject to review and approval by County <br />Surveyor. <br />ACCURACY <br />The CONTRACTOR will be held responsible for the accuracy and completeness of <br />Record Drawings and Electronic As-Builts and shall bear any costs incurred in finding <br />utilities as a result of incorrect data furnished by the CONTRACTOR. <br />01025-17 Technical Specifications <br />F:\Public Works\ENGINEERING DIVISION PROJECTS\1621 IRC Courthouse Judges Security Upgrades\1-Admin\Bid <br />Documents\Master Contract Documents\Technical Specifications.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.