My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
08/15/2017 (3)
CBCC
>
Meetings
>
2010's
>
2017
>
08/15/2017 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2025 2:52:19 PM
Creation date
10/26/2017 3:25:19 PM
Metadata
Fields
Template:
Meetings
Meeting Type
BCC Regular Meeting
Document Type
Agenda Packet
Meeting Date
08/15/2017
Meeting Body
Board of County Commissioners
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
821
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />U <br />• <br />• <br />ORDER NO. PSC -2017 -0283 -TRF -El <br />DOCKET NO. 20170069 -El <br />PAGE 9 <br />(� DUKE <br />ENERGY. <br />11.05 UNDERGROUND SERVICE LATERALS <br />Attachment A <br />Page 3 of <br />SECTION NO.N <br />$li1�t@l REVISED SHEET NO. 4.1`15 <br />CANCELS SEEM HSEVENTEENTH REVISED SHIT NO. 4.1115 <br />OVERHEAD SERVICES: <br />AppfirabSdy <br />When requested by the Applicant the Company will install underground service laterals from e>osting <br />overhead fines as replacements for ensCng overhead services to exiling residential buildings containing <br />less than five (5) separate chwEng units. <br />Rearrangement of Service Entrance: <br />The Applicant stall be responsible for any necessary marangirg of his ersti g electric service entrance <br />facilities to accormtodale the proposed underground service lateral in accordance with the Company's <br />specifications. <br />Trenching: <br />The Applicant shall also provide. at no cost to the Company, a suitable trench and perform the b3cMing <br />and any Lardscapr g, pavement, or other suitable repairs. If the Applicant requests Ore Company to supply <br />ft trench or rerr oae any additional equipmerd other than the Service Lateral, the charge to the Applicant <br />for this work shall be based on aspecific cost estonate. <br />Contribution by Applicant <br />The charge excluding trenchlrQ costs shag be as follows <br />For Service Lateral ......... ............................................... _......... _._..... .............. SeT.3;;40D per service <br />11.06 UNDERGROUND DISTRIBUTION FACILITIES TO 6RILTIPLE-OCCUPANCY RESIDENTIAL BUILDINGS: <br />(1) Awilabifidy. <br />Underground d electric distribution facilities may be Installed within the tract of land upon which multiple - <br />occupancy residential buildings containing five (5) er r om separate dwelling units will be constructed. <br />(2) Conbib ton by Applicant <br />There will be no contribution from the Apploant so long as the Canpany is free to construct the extension in <br />the most economical manner, and reasonably full use is made of the tract of land upon which the mulApte <br />coauparwy buildings will be constructed. Other conditions will requirea contribution from the Applicant. <br />(3) Responsibility of Applicant: <br />(a) Fumish de`a0s and specifications of the proposed building or complex ot buildings. The Corpanywi0 <br />use these in the design of the electric dstrfbution faa ties required to render service. <br />(b) Where the Campany determines Ota, transformers am to be Iocaled Inside the balding. the Applicant <br />shall provide: <br />i. The vadt or vwAs necessary for (e transformers and the associated equipment, including the <br />venala5on egaipmem. <br />ii. The necessary raceways or conduit for Che Comparys supply cables from the vauk or vaults to a <br />suitable point five (5) feet outside the building in aerndance with the Company`s pians and <br />spedSrations. <br />in. Conduits underneath all buuildingswhen required for the Company's supply cables. Such conduits <br />shall extend fere (5) feet beyond the edge of the buddingsforjoining to the Company's facilities. <br />H. The service entrance condudrns and raceways from the Applicants service equipment to the <br />designated point of deliverywit in the vau1L <br />ISSUED BY: JavierJ. Portuondo, Director, Rates 8 Regulatory Strategy — FL <br />EFFECTIVE: JWy 30+.3Gii <br />(Continued on Next Page) <br />
The URL can be used to link to this page
Your browser does not support the video tag.