Laserfiche WebLink
SPECIAL CONDITIONS FOR PERMIT NO. 17-33 <br />FOR <br />INDIAN RIVER COUNTY PUBLIC WORKS DEPARTMENT <br />REPLACEMENT OF EXISTING FAILED CULVERT IN <br />SUB -LATERAL C-1 (IST STREET, SW) CANAL UNDER 74TH AVENUE <br />(DISCHARGING INTO LATERAL "C" CANAL) WITH <br />50 L.F. OF 12011 A.C.M.P. <br />1) This permit is issued based on plans (5 sheets) (County Project # IRC -1737) <br />prepared by Engineering Division, Indian River County Department of Public <br />Works, dated November 13-15, 2017. <br />2) Proposed 120" A.C.M.P. culvert shall be installed with an East Invert of 11.3 <br />and a West Invert of 11.4 (N.A.V.D. '88). <br />3) Blockage of flow in the Lateral "C" (74th Avenue) Canal is strictly prohibited. <br />Any temporary blockage of flow in Sub -lateral C-1 (1St Street, SW) Canal <br />shall be coordinated and approved by David E. Gunter, Superintendent of the <br />Indian River Farms Water Control District prior to commencement of project. <br />4) Any proposed roadway (74th Avenue) swale drainage into Sub -lateral C-1 <br />Canal shall be through drop pipe discharge culvert. <br />5) All final grading at project site shall be away from top of canal banks with <br />sufficient drainage to prevent accumulation of surface water resulting in <br />overbank discharge into canal. <br />J.-WEOSPEC COND-PROVISM2017 PermitsUdwcd spec Gond 17-33.docx <br />