My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-080
CBCC
>
Official Documents
>
2010's
>
2018
>
2018-080
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2020 1:55:26 PM
Creation date
5/3/2018 2:53:07 PM
Metadata
Fields
Template:
Official Documents
Official Document Type
Work Order
Approved Date
05/01/2018
Control Number
2018-080
Agenda Item Number
8.Q.
Entity Name
REI Engineers
Subject
Roof Replacement at Indian River County (IRC) North County RO Water Plant
Area
7751 58th Avenue, Vero Beach
Project Number
1802
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REI ENGINEERS EXHIBIT 'A' <br />< 10150 Highland Manor Drive, Suite 200, Tampa, FL 33610 <br />PHONE 813.944.2137 Fax 813.41.9.7302 <br />January 16, 2018 <br />Indian River County <br />1801 27th Street <br />Vero Beach, FL 32960 <br />Attention: Andrew Sobczak <br />Infrastructure Project Manager <br />Reference: Proposal for Engineering Services <br />Indian River North RO Water Treatment Plant <br />Contract Documents and Construction Administration <br />REI Proposal No. P17TPA-039 Revision 3 <br />Dear Mr. Sobczak: <br />In response to our recent discussions, we are pleased to submit this proposal for your consideration. The <br />roof areas outlined in this proposal include roof sections of the facility located at 7751 58`x' Ave,Vero Beach, <br />Florida 32967 (totaling approximately 16,855 square feet). The following -is an outline of the proposed <br />services for Contract Documents and Construction Administration: <br />I. CONTRACT DOCUMENTS <br />A. Conduct the site visit(s) to develop detailed Contract Documents for the subject building. <br />B. Extract roof samples to identify roof system composition and condition. Cored locations <br />to be repaired with compatible materials. <br />C. Perform the following engineering design calculations for all roof areas which will be <br />sealed by a Licensed Engineer: <br />1. Determine design wind loads in accordance with ASCE 7 as required by the current <br />edition of the State Building Code. <br />2. Primary and secondary (overflow) drainage for compliance with the current edition <br />of the State Plumbing Code. <br />3. Existing and proposed roof system R -Value for compliance with the current edition <br />of the State Energy Conservation Code. <br />4. Estimate existing and proposed roof system dead load unit weights to determine <br />load change and the need for a structural analysis. If a structural .analysis is <br />required, REI will coordinate applicable work with a licensed Structural Engineer. <br />The cost for the structural analysis (if necessary) is not included in this proposal. <br />D. Prepare comprehensive scaled drawings for conditionspresent to ensure competitive bids <br />are received. All plans and details to be developed on Computer Aided Drafting <br />(AutoCAD). <br />ROOFING, WATERPROOFING AND BUILDING ENVELOPE ENGINEERS AND CONSULTANTS <br />www.reiengineers.com <br />AN EMPLOYEE -OWNED COMPANY <br />
The URL can be used to link to this page
Your browser does not support the video tag.