Laserfiche WebLink
A. Manufacturer's Guarantee: Manufacturer's standard form, non pro-rated, without <br /> monetary limitation or deductibles, in which manufacturer agrees to repair or replace <br /> components of roofing system that fail in materials or workmanship within specified <br /> warranty period. Failure includes roof leaks or breaches in the primary roof membrane <br /> causing moisture to enter the substrate below(even if visible leaks are not observed inside <br /> the facility). Warranty to remain in effect for wind speeds up to 72 mph. Warranties <br /> requiring the Owner's signature will not be acceptable. <br /> 1. Warranty to include but not be limited to membrane, insulation, adhesives, <br /> fasteners,sealants,flashings,polymer clad sheet metal,etc. <br /> 2. Warranty Period: Twenty years from date of Substantial Completion. <br /> 3. Manufacturer's Representative shall attend two post construction field inspections: <br /> the first no earlier than twenty-three(23)months and no later than twenty-four(24) <br /> months after the date of Substantial Completion and the second no earlier than fifty- <br /> nine(59)months and no later than sixty(60)months. Submit a written report within <br /> seven(7)days of the site visits to the Engineer listing observations, conditions and <br /> any recommended repairs or remedial action. <br /> PART 2 PRODUCTS <br /> 2.01 MANUFACTURER <br /> A. Membrane materials shall be manufactured by the following: <br /> 1. Sika Sarnafil <br /> 2. Fibertite <br /> 2.02 MEMBRANE MATERIALS <br /> A. Mechanically Attached Membrane and Components: <br /> 1. Membrane <br /> a. Sika Sarnafil,60 mil, S327 <br /> b. Fibertite 36 mil SM <br /> 2. Coverstrip: Shall be 8"wide pre-cut polyester reinforced flashing strip. <br /> 3. Membrane Fasteners and Plates/Attachment Bar: Shall be approved and provided <br /> by membrane manufacturer for the deck type and membrane configuration. <br /> a. Fastener shall be phillips head, carbon steel fastener with corrosion <br /> resistant coating designed for use with specified plate meeting the <br /> following minimum requirements: <br /> i. Shank diameter: .21" <br /> ii. Thread diameter: .26" <br /> iii. Head diameter: .435" <br /> iv. Thread density: 13 turns per inch. <br /> 2.03 RELATED MATERIALS <br /> A. Flashing/Stripping Membrane: Shall be a non fleeceback, thermoplastic membrane <br /> reinforced with fiberglass. Utilize asphalt resistant flashing membrane where in contact <br /> with residual asphaltic materials or as required by the manufacturer. <br /> Sebastian Corners Roof Replacement 07 54 00-4 Thermoplastic Single Ply Roofing <br />